Endoscopic Ultrasonography-Guided Fine-Needle Aspiration for Duodenal Subepithelial Lesions Showing a Hypoechoic Mass on Endoscopic Ultrasound Imaging.
Аннотация
BACKGROUND/AIMS: For duodenal subepithelial lesions showing a hypoechoic mass on endoscopic ultrasound imaging, the utility of endoscopic ultrasound-guided fine-needle aspiration and the frequency of histological types have not been the focus of previous literature. This study aimed to clarify this.
MATERIALS AND
METHODS
This prospective observational study enrolled 22 consecutive patients who underwent endoscopic ultrasoundguided fine-needle aspiration for duodenal subepithelial lesions with hypoechoic mass on endoscopic ultrasound. Immunohistochemical analysis was performed for all endoscopic ultrasound-guided fine-needle aspiration and surgically resected specimens. The main outcome measures were the technical results of endoscopic ultrasound-guided fine-needle aspiration and the frequency of histological types of duodenal subepithelial lesions with hypoechoic mass.
RESULTS
Thirteen fine-needle aspiration specimens were obtained from the duodenal bulb and eight from the descending duodenal region. The puncture was not performed because of intervening vessels in one patient. The diagnostic rate was 81% (95% confidence interval: 58.1-94.6, 17/21 patients). In 12 patients receiving surgical resection (excluding one cancellation of endoscopic ultrasoundguided fine-needle aspiration), the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration was 75% (95% confidence interval: 42.8-94.5, 9/12 patients). No complications were observed. The histopathological diagnoses included 11 cases of gastrointestinal stromal tumor (50%), 2 cases of leiomyoma (9%), 2 cases of metastatic cancer (9%), 2 cases of benign inconclusive, and 1 case each of carcinoid, malignant lymphoma, leiomyosarcoma, gauzeoma, and aberrant pancreas (4.5% each). The frequency of malignant tumors in the duodenal subepithelial lesions with hypoechoic mass group was 73% (16/22 patients).
CONCLUSIONS
Endoscopic ultrasound-guided fine-needle aspiration for duodenal subepithelial lesions with hypoechoic mass was safe and accurate. As duodenal subepithelial lesion with hypoechoic mass has a reasonably high possibility of containing malignant tumors, it is desirable to perform endoscopic ultrasound-guided fine-needle aspiration.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.