Preliminary Evaluation of Aortic Aneurysm Screening Using Oscillometric Device Equipped With Novel Algorithm Analyzing Pulse Wave Transfer.

Ichihashi Shigeo, Hashimoto Tomoko, Iwakoshi Shinichi, Obayashi Kenji, Saeki Keigo, Kichikawa Kimihiko

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Detection of aortic aneurysm (AA) prior to rupture is crucial to decreasing its mortality. Towards this purpose, a novel detection algorithm was developed from pulse volume recording (PVR), analyzing the propagation loss of pulse waves caused by expansion of the aortic wall. The diagnostic ability of the algorithm was evaluated in this prospective study.

METHODS AND

RESULTS

PVR were measured for 30 s using the oscillometric device designed for automatic measurement of the ankle-brachial index (ABI). The algorithm processed the data automatically and assessed whether the patient had an AA. CT angiography was used as the reference standard. Sensitivity and specificity of the algorithm were evaluated. A total of 152 AA patients, including 21 patients with thoracic AAs (TAA), and 64 non-aneurysm control subjects were enrolled. The mean diameter of all AAs was 47.2±10.3 mm. After measurements, 121 AA patients and 33 control subjects were judged by the algorithm as having or not having AAs, resulting in sensitivity of 80% and specificity of 52%. The sensitivity was higher for larger AAs. There was no sensitivity difference according to the location of the AA.

CONCLUSIONS

The new diagnostic algorithm installed in the oscillometric device detected AAs with high sensitivity, especially larger aneurysms. For application as a screening tool, the specificity needs to be improved.

Для цитирования: Ichihashi Shigeo, Hashimoto Tomoko, Iwakoshi Shinichi, Obayashi Kenji, Saeki Keigo, Kichikawa Kimihiko. Preliminary Evaluation of Aortic Aneurysm Screening Using Oscillometric Device Equipped With Novel Algorithm Analyzing Pulse Wave Transfer.. Circulation journal : official journal of the Japanese Circulation Society. 2017. DOI: 10.1253/circj.cj-17-0462.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.