Effect of the Number and Angulation of Implants on the Accuracy of Digital Impression in Completely Edentulous Arches.

Kim Yuyeon, Kim Donghyun, Son Hyeonseong, Hong Seoung-Jin, Kim Hyeong-Seob, Pae Ahran

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of impression methods using an intraoral scanner and the conventional method based on the implant number and angulation with multiple implants.

MATERIALS AND

METHODS

Six implants were placed in the maxillary edentulous typodont using 3D-modeling software. Eight implants were placed in another maxillary edentulous typodont. The implant placement angulation for each model was different. 3D designing and printing were performed to produce reference models. These models were scanned to obtain reference scan data (RSD). In the conventional impression method, reference models were used, and a gypsum model was produced. Scan data was obtained by the lab scanner (Group CI). Models were scanned, and the scan data was obtained (Group IS). The distance and angulation deviation were compared.

RESULTS

In models with six implants, the mean values of all distance and angulation deviations were less in Group CI than in Group IS (P < .05), except for the distance deviation in Model 6-20. In models with eight implants, the mean values of distance and angulation deviations were less in Group CI than in Group IS, except for the distance deviation in Model 8-20, and significant differences were observed between the two groups for Models 8-0, 8-10, and 8-20 (P < .05).

CONCLUSIONS

In cases where multiple implants are placed in the completely edentulous arch in vitro, conventional impressions are more accurate than intraoral scans. In cases lacking implant parallelism, intraoral scans can be used as a replacement for conventional impressions.

Для цитирования: Kim Yuyeon, Kim Donghyun, Son Hyeonseong, Hong Seoung-Jin, Kim Hyeong-Seob, Pae Ahran. Effect of the Number and Angulation of Implants on the Accuracy of Digital Impression in Completely Edentulous Arches.. The International journal of prosthodontics. 2025. DOI: 10.11607/ijp.9174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.