Predictors of Permanent Pacemaker Implantation Following Valve-in-Valve Transcatheter Aortic Valve Replacement.

Quelal Analuisa Karol, Arya Namrata, Donisan Teodora, Harmon David, Alkhouli Mohamad, Sugrue Alan M, Cha Yong-Mei, Mackram Eleid F, Deshmukh Abhishek J

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is increasingly used to treat structural valve degeneration. Permanent pacemaker implantation (PPI) following TAVR is associated with increased morbidity and mortality, yet predictors specific to ViV-TAVR remain poorly defined.

OBJECTIVE

To identify clinical and procedural predictors of PPI in patients undergoing ViV-TAVR.

METHODS

We conducted a retrospective observational study of consecutive ViV-TAVR cases at the Mayo Clinic from 2012 to 2022. Clinical, ECG, procedural data and fluoroscopic measurements were analyzed, and propensity score matching was used to adjust for confounding. Predictors of PPI were identified using multivariable logistic regression.

RESULTS

Among 261 patients, 24 (9.2%) underwent PPI. Balloon-expandable valves were used in 66.7% and self-expanding valves in 33.3%. Predictors of PPI included Preprocedural bifascicular block (OR 12.15, 95% CI: 2.52-68.89, p = 0.003), greater septal implantation depth (OR 1.29, 95% CI: 1.04-1.65, p = 0.019), and post-procedural new left (OR 23.56, 95% CI: 4.91-48.52, p = 0.0004) and right bundle branch blocks (OR 24.4, 95% CI: 3.82-30.51, p = 0.001). Aortic regurgitation as the mechanism of prosthetic valve failure was associated with reduced PPI odds (OR 0.28, 95% CI: 0.10-0.76, p = 0.014). Pacing requirement-defined as > 90% ventricular pacing-increased from 25% at 3 months to 56.25% at 12 months. At a median follow-up of 962.5 days (IQR 481.5-1555.3), adjusted mortality was significantly higher in the PPI group (aOR 9.4, 95% CI: 1.9-60.4, p = 0.028).

CONCLUSION

Bifascicular block, greater septal depth, and new bundle branch blocks predict PPI post-ViV-TAVR, while aortic regurgitation appears protective. Risk stratification and procedural planning are critical.

Для цитирования: Quelal Analuisa Karol, Arya Namrata, Donisan Teodora, Harmon David, Alkhouli Mohamad, Sugrue Alan M, Cha Yong-Mei, Mackram Eleid F, Deshmukh Abhishek J. Predictors of Permanent Pacemaker Implantation Following Valve-in-Valve Transcatheter Aortic Valve Replacement.. Journal of cardiovascular electrophysiology. 2025. DOI: 10.1111/jce.70139.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.