MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13669

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2019

Patient characteristics as predictors of recurrence of atrial fibrillation following cryoballoon ablation.

Bavishi Aakash A, Kaplan Rachel M, Peigh Graham, Diaz Celso L, Baman Jayson R, Trivedi Amar, Wasserlauf Jeremiah, Shen Mark J, Sattayaprasert Prasongchai, Chicos Alexandru B, Kim Susan, Verma Nishant, Arora Rishi, Lin Albert, Knight Bradley P, Passman Rod S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

While several studies have evaluated predictors for atrial fibrillation (AF) recurrence following catheter ablation, there are limited data specific to cryoballoon ablation (CBA).

METHODS

We analyzed a prospective registry of patients at a single institution who underwent CBA. Recurrence of AF (RAF) was defined as recurrence of AF by 12-month follow-up, excluding the 3-month blanking period. Univariate analysis was performed to evaluate predictors of RAF. Receiver operating characteristic analysis was used to compare and evaluate the performance of various risk scores for discriminating risk of RAF.

RESULTS

There were 542 patients included in the analysis with mean age 61.3 ± 10.6 years, 67.9% male, and 51.6% paroxysmal AF (PAF). Overall, only left atrial diameter (LAD) > 40 mm and ERAF (early recurrence of AF within 0-3 month blanking period) were significant predictors of RAF. In the PAF specific subgroup, LAD > 40 mm, AF duration > 12 months, prior stroke or transient ischemic attack, ERAF, and having previously failed an antiarrhythmic drug were significant predictors of RAF. In persistent AF (PeAF) subgroup, obstructive sleep apnea (OSA) and ERAF were significant predictors of RAF. Out of clinical risk scores tested, BASEAF2 had the highest performance with area under the curve of 0.646 (95% confidence interval [0.548, 0.708]; P < .01).

CONCLUSIONS

In this single-center retrospective study of CBA, we found only LAD > 40 mm and ERAF to be predictors of RAF. We identified OSA as a potential targetable risk factor in PeAF patients undergoing CBA. Out of risk scores tested for discriminating risk of RAF, BASEAF2 had the best performance.

Для цитирования: Bavishi Aakash A, Kaplan Rachel M, Peigh Graham, Diaz Celso L, Baman Jayson R, Trivedi Amar, Wasserlauf Jeremiah, Shen Mark J, Sattayaprasert Prasongchai, Chicos Alexandru B, Kim Susan, Verma Nishant, Arora Rishi, Lin Albert, Knight Bradley P, Passman Rod S. Patient characteristics as predictors of recurrence of atrial fibrillation following cryoballoon ablation.. Pacing and clinical electrophysiology : PACE. 2019. DOI: 10.1111/pace.13669.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.