Associations of High Intensities on Magnetization-Prepared Rapid Acquisition with Gradient Echo with Aortic Complicated Lesions in Ischemic Stroke Patients.

Yamaguchi Yoshitaka, Tanaka Tomotaka, Morita Yoshiaki, Yoshimura Sohei, Koga Masatoshi, Ihara Masafumi, Toyoda Kazunori

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Aortic complicated lesions (ACLs) are key parameters for evaluating aortic embolic sources in embolic stroke, and are usually diagnosed using transesophageal echocardiography (TEE). However, alternative methods for diagnosing ACLs have not been well established. We investigated associations between high-intensity areas on T1-weighted imaging (T1WI) with magnetization-prepared rapid acquisition with gradient echo (MPRAGE) and ACLs on TEE among ischemic stroke patients.

METHODS

Participants comprised 135 patients (mean age, 71 years; 35 women) with ischemic stroke or transient ischemic attack who underwent TEE for evaluation of embolic sources and plaque imaging using MPRAGE for evaluation of aortic or carotid plaques. Aortic plaque with signal intensity ≥200% of sternocleidomastoid intensity on MPRAGE was categorized as "high intensity". ACLs on TEE were defined by focal increases in intima-media thickness (IMT) ≥4.0 mm or the presence of ulcerated or mobile plaques.

RESULTS

Fifty-six patients (42%) showed high-intensity areas on MPRAGE at the aortic arch. Aortic maximum IMT was significantly higher in patients with high intensities than in those without (p < 0.001). Incidences of ACLs (66 vs. 20%, p < 0.001) or ulcerated or mobile plaques (30 vs. 6%, p < 0.001) were significantly higher in patients with high intensities than in patients without. Multivariable logistic regression analysis showed that high intensities on MPRAGE were independently associated with the presence of ACLs (OR 5.72; 95% CI 2.38-13.70) and ulcerated or mobile plaques (OR 4.18; 95% CI 1.29-13.50).

CONCLUSIONS

High intensities on T1WI with MPRAGE in the aortic arch were significantly associated with the presence of ACLs. An evaluation of the aortic arch using MPRAGE may be useful for predicting ACLs.

Для цитирования: Yamaguchi Yoshitaka, Tanaka Tomotaka, Morita Yoshiaki, Yoshimura Sohei, Koga Masatoshi, Ihara Masafumi, Toyoda Kazunori. Associations of High Intensities on Magnetization-Prepared Rapid Acquisition with Gradient Echo with Aortic Complicated Lesions in Ischemic Stroke Patients.. Cerebrovascular diseases (Basel, Switzerland). 2019. DOI: 10.1159/000497068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.