BMC research notes · 2020
Newborn screening for congenital hypothyroidism: improvement in short-term follow-up by audit and monitoring.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Majid Hafsa, Ahmed Sibtain, Siddiqui Imran, Humayun Khadija, Karimi Hussain, Khan Aysha Habib
Аннотация
OBJECTIVE: Newborn screening for congenital hypothyroidism (CH) at our hospital during this study was by measurement of thyroid stimulating hormone (TSH) in serum samples. This audit was conducted over a 2 year period, to determine the compliance of reporting of results greater than the screening cutoffs for serum TSH. Gaps of non-compliance were identified, and re-audit was undertaken after the corrective actions were taken.
RESULTS: The critical limit was defined as serum TSH (≥ 20 µIU/ml) following consultation with a pediatric endocrinologist. All results above this limit were reported urgently to physicians. During the audit period, 27,407 tests were performed, 0.7% had a value of ≥ 20 µIU/ml, of those only 62% were reported to the general paediatrician or neonatologist. Reasons for not reporting results included non-availability of contact information, lack of policy awareness by technologists, critical results not highlighted on the computer display, and absence of regular monitoring. Corrective measures were taken, and re-audit was done. During the re-audit period, a total of 22,985 tests was performed, 0.6% had a value of ≥ 20 µIU/ml. Of these, 77% were reported to the general paediatrician or neonatologist. Critical result reporting was improved after the audit, and further enhanced the laboratory service of CH screening.
RESULTS: The critical limit was defined as serum TSH (≥ 20 µIU/ml) following consultation with a pediatric endocrinologist. All results above this limit were reported urgently to physicians. During the audit period, 27,407 tests were performed, 0.7% had a value of ≥ 20 µIU/ml, of those only 62% were reported to the general paediatrician or neonatologist. Reasons for not reporting results included non-availability of contact information, lack of policy awareness by technologists, critical results not highlighted on the computer display, and absence of regular monitoring. Corrective measures were taken, and re-audit was done. During the re-audit period, a total of 22,985 tests was performed, 0.6% had a value of ≥ 20 µIU/ml. Of these, 77% were reported to the general paediatrician or neonatologist. Critical result reporting was improved after the audit, and further enhanced the laboratory service of CH screening.