Highly undersampled supraaortic MRA at 3.0 T: initial results with parallel imaging in two directions using a 16-channel neurovascular coil and parallel imaging factors up to 16.

Kukuk Guido M, Hadizadeh Dariusch R, Gieseke Jürgen, von Falkenhausen Marcus, Böhm Ingrid, Semrau Renate, Urbach Horst, Koscielny Arne, Verrel Frauke, Wilhelm Kai, Schild Hans H, Willinek Winfried A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To present the feasibility of highly undersampled contrast-enhanced MRA (CE-MRA) of the supraaortic arteries with a 16-channel neurovascular coil at 3.0 T using parallel imaging in two directions with parallel imaging factors (PIF) up to 16.

MATERIALS AND

METHODS

Institutional review board approval and informed consent were obtained. In a prospective study, MRA protocols including PIF of 1, 2, 4, 9 and 16 yielding a spatial resolution from 0.81×0.81×1.0 mm(3) to 0.46×.46×0.98 mm(3) were acquired. In 32 examinations, image quality and vascular segments were rated independently by two radiologists. SNR estimations were performed for all MRA protocols.

RESULTS

The use of high PIF allowed to shorten acquisition time from 2:09 min down to 1:13 min and to increase the anatomic coverage while maintaining or even increasing spatial resolution down to 0.46×0.46×0.98 mm(3). The larger anatomic coverage that was achieved with the use of high PIF allowed for visualization of vascular structures that were not covered by the standard protocols. Despite the resulting lower SNR using high PIF, image quality was constantly rated to be adequate for diagnosis or better in all cases.

CONCLUSION

The use of high PIF yielded diagnostic image quality and allowed to increase the anatomic coverage while maintaining or even improving spatial resolution and shortening the acquisition time.

Для цитирования: Kukuk Guido M, Hadizadeh Dariusch R, Gieseke Jürgen, von Falkenhausen Marcus, Böhm Ingrid, Semrau Renate, Urbach Horst, Koscielny Arne, Verrel Frauke, Wilhelm Kai, Schild Hans H, Willinek Winfried A. Highly undersampled supraaortic MRA at 3.0 T: initial results with parallel imaging in two directions using a 16-channel neurovascular coil and parallel imaging factors up to 16.. Magnetic resonance imaging. 2010. DOI: 10.1016/j.mri.2010.06.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.