MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2009.10.008

Медицинская библиотека · JACC. Cardiovascular interventions · 2009

Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).

Leon Martin B, Kandzari David E, Eisenstein Eric L, Anstrom Kevin J, Mauri Laura, Cutlip Donald E, Nikolsky Eugenia, O'Shaughnessy Charles, Overlie Paul A, Kirtane Ajay J, McLaurin Brent T, Solomon Stuart L, Douglas John S, Popma Jeffrey J, ENDEAVOR IV Investigators

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to assess, after 2 years of follow-up, the safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent (ZES) compared with a paclitaxel-eluting stent (PES) in patients with native coronary lesions.

BACKGROUND

Early drug-eluting stents were associated with a small but significant incidence of very late stent thrombosis (VLST), occurring >1 year after the index procedure. The ZES has shown encouraging results in clinical trials.

METHODS

The ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions), a randomized (1:1), single-blind, controlled trial (n = 1,548) compared ZES versus PES in patients with single de novo coronary lesions. Two-year follow-up was obtained in 96.0% of ZES and 95.4% of PES patients. The primary end point was target vessel failure (TVF), and safety end points included Academic Research Consortium-defined stent thrombosis. Economic end points analyzed included quality-adjusted survival, medical costs, and relative cost-effectiveness of ZES and PES.

RESULTS

The TVF at 2 years was similar in ZES and PES patients (11.1% vs. 13.1%, p = 0.232). There were fewer myocardial infarctions (MIs) in ZES patients (p = 0.022), due to fewer periprocedural non-Q-wave MIs and fewer late MIs between 1 and 2 years. Late MIs were associated with increased VLST (PES: 6 vs. ZES: 1; p = 0.069). Target lesion revascularization was similar comparing ZES with PES (5.9% vs. 4.6%; p = 0.295), especially in patients without planned angiographic follow-up (5.2% vs. 4.9%; p = 0.896). The cost-effectiveness of ZES and PES was similar.

CONCLUSIONS

After 2 years of follow-up, ZES demonstrated efficacy and cost-effectiveness comparable to PES, with fewer MIs and a trend toward less VLST. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).

Для цитирования: Leon Martin B, Kandzari David E, Eisenstein Eric L, Anstrom Kevin J, Mauri Laura, Cutlip Donald E, Nikolsky Eugenia, O'Shaughnessy Charles, Overlie Paul A, Kirtane Ajay J, McLaurin Brent T, Solomon Stuart L, Douglas John S, Popma Jeffrey J, ENDEAVOR IV Investigators. Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).. JACC. Cardiovascular interventions. 2009. DOI: 10.1016/j.jcin.2009.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.