MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1258/ar.2011.100421

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2011

Detection of unruptured cerebral artery aneurysms by MRA at 3.0 tesla: comparison with multislice helical computed tomographic angiography.

Numminen Jussi, Tarkiainen Antti, Niemelä Mika, Porras Matti, Hernesniemi Juha, Kangasniemi Marko

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomographic angiography (CTA) has become the primary non-invasive method for detection of cerebral artery aneurysms in many neurovascular centers.

PURPOSE: To compare MR-angiography at a 3.0 tesla (3T) scanner to CTA in the detection of unruptured intracranial aneurysms.

MATERIAL AND

METHODS

CTA and 3T MRA data from 60 patients were evaluated. CTA was obtained with a 4-16-row helical CT-scanner after administration of 120 cc intravenous contrast agent, MRA was performed by a 3T MR-scanner using time-of-flight pulse sequence.

RESULTS

Fifty-five cerebral artery aneurysms were detected by MRA and 47 aneurysms by CTA. Most of the aneurysms detected by MRA but not by CTA were small internal carotid artery (ICA) aneurysms. Bone structures and venous enhancement deteriorated CTA accuracy, especially in skull base. In one patient a fairly large anterior communicating artery aneurysm was not visible in MRA due to spin saturation, although it was clearly visualized in CTA. After contrast injection the aneurysm was also seen in MRA. Although the overall image quality of MRA and CTA were comparable, MRA was more susceptible to artifacts and thus re-formatted surface-shaded volume rendered 3-dimensional images of aneurysms from MRA were inferior compared to those from CTA.

CONCLUSION

MRA at 3T appears to be at least as sensitive as CTA in the detection of unruptured cerebral artery aneurysms, however image quality control is crucial and contrast agent enhances visualization of complex and large aneurysms.

Для цитирования: Numminen Jussi, Tarkiainen Antti, Niemelä Mika, Porras Matti, Hernesniemi Juha, Kangasniemi Marko. Detection of unruptured cerebral artery aneurysms by MRA at 3.0 tesla: comparison with multislice helical computed tomographic angiography.. Acta radiologica (Stockholm, Sweden : 1987). 2011. DOI: 10.1258/ar.2011.100421.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.