MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rli.0b013e31817d1505

Медицинская библиотека · Investigative radiology · 2008

Intra-individual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraaortic vessels at 3 Tesla.

Bueltmann Eva, Erb Gunter, Kirchin Miles A, Klose Uwe, Naegele Thomas

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare gadobenate dimeglumine (Gd-BOPTA) and gadopentetate dimeglumine (Gd-DTPA) for contrast-enhanced magnetic resonance (MR) angiography of the supraaortic vessels at 3 Tesla.

MATERIALS AND

METHODS

Twelve healthy volunteers each underwent two contrast-enhanced magnetic resonance angiography examinations, one with Gd-BOPTA and one with Gd-DTPA each at a dose of 0.1 mmol/kg bodyweight. The 2 examinations were performed in randomized order and were separated by at least 72 hours. Imaging was performed in the coronal plane at 3T (Magnetom TIM Trio Siemens) using a 12-channel neurovascular array coil. The MR sequence parameters were identical for all examinations. Maximum intensity projection reconstructions were evaluated separately and in matched-pairs by a single independent blinded reviewer in terms of qualitative (5-point scales for technical quality and vessel delineation) and quantitative (relative contrast-to-noise ratio) contrast enhancement across 19 arteries/arterial segments comprising the internal carotid arteries; anterior, middle, and posterior cerebral arteries; vertebral arteries; and basilar artery. Findings were compared using the Wilcoxon signed rank test.

RESULTS

The mean technical quality across all examinations was significantly (P = 0.031) greater after Gd-BOPTA. The overall median score for vessel delineation was also significantly higher for Gd-BOPTA than for Gd-DTPA (4.3 vs. 3.7; P = 0.005). Matched-pairs assessment revealed significant (P <or= 0.026) preference for Gd-BOPTA both globally and for assessments of the extracranial arteries, Circle of Willis and vessels distal to the Circle of Willis. The relative contrast-to-noise ratio was significantly (P <or= 0.021) greater after Gd-BOPTA, with overall increases of 23.3%, 26.7%, and 28.5% noted for the internal carotid, middle cerebral, and basilar arteries, respectively.

CONCLUSION

Significantly improved image quality and contrast enhancement is achieved at 3T with 0.1 mmol/kg Gd-BOPTA compared with 0.1 mmol/kg Gd-DTPA.

Для цитирования: Bueltmann Eva, Erb Gunter, Kirchin Miles A, Klose Uwe, Naegele Thomas. Intra-individual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraaortic vessels at 3 Tesla.. Investigative radiology. 2008. DOI: 10.1097/rli.0b013e31817d1505.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.