DOI 10.1097/00002480-200005000-00020

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2000

A bovine model for detecting high intensity transient signals originating from mechanical heart valves.

Conger J L, Deklunder G M, Lecroart J L, LaPeyre D M, Gregoric I, Rose H, Wieting D W, Clubb F, Frazier O H

СтатьяПеревод пока не подготовлен

Аннотация

In patients with mechanical heart valves (MHVs), transcranial Doppler methods commonly detect high intensity transient signals (HITS) representing microemboli. These microemboli, which are presumably gaseous, may cause stroke and cognitive deterioration. A bovine model was therefore developed for studying the relationship between mitral MHV induced HITS and potential etiogenic factors. We placed an 18 mm, 4 MHz Doppler probe in the brachiocephalic artery to detect MHV induced microbubbles at baseline (rest) and under 9 other conditions. To elucidate the gas composition (CO2 or N2) of the microbubbles, we administered 1%, 3%, and 5% CO2, and 100% O2. To determine effect of the heart rate, we paced the heart at 120, 160, and 180 bpm. To alter the myocardial contractility, we gave dobutamine and esmolol. Two independent, blinded observers counted the HITS from recorded doppler spectra. HITS were defined by an initial unidirectional spectral deviation, a signal power of >8 dB relative to the background power, and lack of a cyclic appearance. The electrocardiogram, aortic and LV pressures, and LV dP/dt were obtained telemetrically. The calves were studied 4 to 6, 8 to 10, and 12 to 14 weeks postoperatively, after which the animals were sacrificed at an approximate 4 month study duration, and a postmortem evaluation of the heart and the main viscera was performed. In all, 27 HITS recordings were made in 10 calves. Myocardial contractility was the only factor to significantly affect HITS frequency; the heart rate and blood gas concentrations had minimal effect on HITS frequency. Our bovine model will be useful for assessing valve designs, as well as the mechanism of HITS, the composition of the microemboli, and their possible pathophysiologic effects on the kidneys and brain.

Для цитирования: Conger J L, Deklunder G M, Lecroart J L, LaPeyre D M, Gregoric I, Rose H, Wieting D W, Clubb F, Frazier O H. A bovine model for detecting high intensity transient signals originating from mechanical heart valves.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2000. DOI: 10.1097/00002480-200005000-00020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.