Doppler pressure half-time method of assessing mitral valve area: aortic insufficiency does not adversely affect validity.

Robiolio P A, Rigolin V H, Harrison J K, Kisslo K B, Bashore T M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study evaluated the effect of aortic insufficiency on the correlation of pressure half-time-derived mitral valve area with each of 2 standards for mitral valve area (planimetry and cardiac catheterization) in a prospectively assembled cohort of patients scheduled for percutaneous balloon mitral commissurotomy.

BACKGROUND

Although Doppler pressure half-time has been validated as a method for assessing mitral valve area, most previous studies have suggested that this noninvasive technique overestimates mitral valve area in the setting of coexistent aortic insufficiency.

METHODS AND

RESULTS

Echocardiography and cardiac catheterization were performed on 212 consecutive patients scheduled for percutaneous balloon mitral commissurotomy. After excluding 35 patients who did not have aortography, the rest were divided into a "no aortic insufficiency [AI] group" (n = 146) including those with trivial or no aortic insufficiency at catheterization and an "AI group" (n = 31 ) including those with mild or moderate aortic insufficiency. The pressure half-time mitral valve area tended to slightly underestimate invasive valve area by 0.04 cm2 in the AI group and to slightly overestimate invasive valve area by 0.06 cm2 in the no AI group. This difference between the groups was not statistically significant (P = .13). The pressure half-time mitral valve area tended to underestimate planimetered valve area by 0.11 cm2 in the AI group and by 0.10 cm2 in the no AI group. There was no difference between the 2 groups (P = .94). Potential confounders that could theoretically mask the effect of aortic insufficiency on the pressure half-time (including age, heart rate, blood pressure, left ventricular diastolic pressure, ejection fraction, mitral regurgitation, and atrial fibrillation) were excluded by multivariable analyses.

CONCLUSIONS

The pressure half-time method of determining mitral valve area is not adversely affected by mild to moderate aortic insufficiency. This finding has implications for the utility of this technique in the rheumatic valvular disease population, in which mitral and aortic valve disease frequently coexist.

Для цитирования: Robiolio P A, Rigolin V H, Harrison J K, Kisslo K B, Bashore T M. Doppler pressure half-time method of assessing mitral valve area: aortic insufficiency does not adversely affect validity.. American heart journal. 1998. DOI: 10.1016/s0002-8703(98)70021-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.