Dental and medical problems · 2019
Comparative evaluation of the efficacy of three methods of delivering calcium hydroxide into the root canal.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sharifi Roohollah, Bahrampour Ehsan, Janfroozzade Pourya, Safaei Mohsen, Mozaffari Hamid Reza, Soltanimehr Elham, Moradpoor Hedaiat, Imani Mohammad Moslem
Аннотация
BACKGROUND: Calcium hydroxide, due to its favorable properties, such as an antimicrobial effect as well as its ability to dissolve necrotic tissues, inhibit tooth resorption and stimulate the formation of a hard tissue barrier, is widely used in root canal treatment.
OBJECTIVES: The objective of this study was to compare the efficacy of 3 methods of delivery of calcium hydroxide into the canals.
MATERIAL AND METHODS: This in vitro experimental study was performed on acrylic resin blocks with simulated curved canals (curvature of 24° and 44°). Calcium hydroxide was delivered into the canals with 3 different instruments : a hand file, a Lentulo and a rotary file. The data was analyzed using the three-way analysis of variance (ANOVA) and Tukey's test.
RESULTS: The density of calcium hydroxide was significantly different among the 3 groups (p < 0.001). The manual delivery technique resulted in the lowest and using a rotary file in the highest density of calcium hydroxide (p < 0.001). The mean density of calcium hydroxide was significantly higher in the canals with curvature of 24°, irrespective of the delivery method (p < 0.001). The lowest mean density of calcium hydroxide was noted at 1 mm and 3 mm from the apex, whereas the highest mean density was noted at 11 mm from the apex, irrespective of delivery method (p < 0.001).
CONCLUSIONS: A rotary file seems to be the most efficient instrument for delivering calcium hydroxide into the canals, especially into the apical region of canals with greater curvature.
OBJECTIVES: The objective of this study was to compare the efficacy of 3 methods of delivery of calcium hydroxide into the canals.
MATERIAL AND METHODS: This in vitro experimental study was performed on acrylic resin blocks with simulated curved canals (curvature of 24° and 44°). Calcium hydroxide was delivered into the canals with 3 different instruments : a hand file, a Lentulo and a rotary file. The data was analyzed using the three-way analysis of variance (ANOVA) and Tukey's test.
RESULTS: The density of calcium hydroxide was significantly different among the 3 groups (p < 0.001). The manual delivery technique resulted in the lowest and using a rotary file in the highest density of calcium hydroxide (p < 0.001). The mean density of calcium hydroxide was significantly higher in the canals with curvature of 24°, irrespective of the delivery method (p < 0.001). The lowest mean density of calcium hydroxide was noted at 1 mm and 3 mm from the apex, whereas the highest mean density was noted at 11 mm from the apex, irrespective of delivery method (p < 0.001).
CONCLUSIONS: A rotary file seems to be the most efficient instrument for delivering calcium hydroxide into the canals, especially into the apical region of canals with greater curvature.