MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2019.01.138

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2019

Effects of pulmonary artery banding in doxorubicin-induced left ventricular cardiomyopathy.

Yerebakan Can, Boltze Johannes, Elmontaser Hatem, Yoruker Uygar, Latus Heiner, Khalil Markus, Ostermayer Stefan, Steinbrenner Blanca, Apitz Christian, Schneider Matthias, Suchowski Marcel, Ruetten Rita, Mueller Kristin, Kerst Gunther, Schranz Dietmar, Akintuerk Hakan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Central pulmonary banding has been proposed as a novel alternative for the treatment of left ventricular dilated cardiomyopathy in children. We sought to investigate the effects of central pulmonary banding in an experimental model of doxorubicin-induced left ventricular dilated cardiomyopathy.

METHODS

Four-month-old sheep (n = 28) were treated with intermittent intracoronary injections of doxorubicin (0.75 mg/kg/dose) into the left main coronary artery. A total dose of up to 2.15 mg/kg of doxorubicin was administered until signs of left ventricular dilation with functional impairment occurred by transthoracic echocardiography evaluation. Animals that survived were treated with surgical central pulmonary banding through a left anterior thoracotomy or sham surgery. Transthoracic echocardiography and pressure-volume loop measurements were used to compare left ventricular function preoperatively and 3 months later. Macroscopic and microscopic histologic examinations followed after hearts were harvested.

RESULTS

Nine animals from the central pulmonary banding group and 8 animals from the sham group survived and were included in the final analysis. Both groups showed similar inflammation and fibrosis upon histologic examination consistent with the toxic myocardial effects of doxorubicin. There were no differences in the echocardiographic measurements before central pulmonary banding or sham operation. Baseline measurements before the central pulmonary banding/sham operation were considered as 100%. The central pulmonary banding group had better left ventricular ejection fraction (102.5% ± 21.6% vs 76.7% ± 11.7%, P = .01), with a tendency for smaller left ventricular end-diastolic (101.2% ± 7.4% vs 120.4% ± 10.8%, P = .18) and significantly smaller end-systolic (100.3% ± 12.9% vs 116.5 ± 9.6%, P = .02) diameter of the left ventricle in comparison with the sham animals at 3 months. The end-systolic volume (101.4% ± 31.6% vs 143.4% ± 28.6%, P = .02) was significantly lower in the central pulmonary banding group 3 months postoperatively. Fractional shortening in the long axis (118.5% ± 21.5% vs 85.2% ± 22.8%, P = .016) and short axis (122.5% ± 18% vs 80.9% ± 13.6%, P = .0005) revealed significantly higher values in the central pulmonary banding group. In the conductance catheter measurements, no significant differences were seen between the groups for the parameters of systolic and diastolic function.

CONCLUSIONS

Central pulmonary artery banding in the setting of experimental toxic left ventricular dilated cardiomyopathy improved left ventricular echocardiographic function and dimensions.

Для цитирования: Yerebakan Can, Boltze Johannes, Elmontaser Hatem, Yoruker Uygar, Latus Heiner, Khalil Markus, Ostermayer Stefan, Steinbrenner Blanca, Apitz Christian, Schneider Matthias, Suchowski Marcel, Ruetten Rita, Mueller Kristin, Kerst Gunther, Schranz Dietmar, Akintuerk Hakan. Effects of pulmonary artery banding in doxorubicin-induced left ventricular cardiomyopathy.. The Journal of thoracic and cardiovascular surgery. 2019. DOI: 10.1016/j.jtcvs.2019.01.138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.