Operating room air delivery design to protect patient and surgical site results in particles released at surgical table having greater concentration along walls of the room than at the instrument tray.

Wagner Jennifer A, Dexter Franklin, Greeley Damon G, Schreiber Kevin

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

During the coronavirus disease 2019 (COVID-19) pandemic, recommendations have included that personnel not involved in procedures releasing airborne contaminants reduce their exposure by moving >2 m away. We tested whether air particle concentrations in operating rooms (ORs) are greater in the periphery, downstream from the supply airflow.

METHODS

We analyzed data from 15 mock surgical procedures performed in 3 ORs. Two ORs were modern, one with a single large diffuser system above the surgical table, and the other using a multiple diffuser array design. An air particle counting unit was located on the instrument table, another adjacent to an air return grille.

RESULTS

Concentrations of air particles were greater at return grille than instrument table for the single large diffuser at 26 air exchanges per hour, and the multiple diffuser array at both 26 and 20 air exchanges per hour (all P ≤ .0044), including during electrocautery (all P ≤ .0072). The ratios of concentrations, return grille versus instrument table, were greater during electrocautery for 0.5 to 1.0-micron particles and 1.0 to 5.0-micron particles (both P < .0001).

CONCLUSIONS

Modern OR airflow systems are so effective at protecting the surgical field and team from airborne particles emitted during surgery that concentrations of particles released at the OR table are greater at the OR walls than near the center of the room.

Для цитирования: Wagner Jennifer A, Dexter Franklin, Greeley Damon G, Schreiber Kevin. Operating room air delivery design to protect patient and surgical site results in particles released at surgical table having greater concentration along walls of the room than at the instrument tray.. American journal of infection control. 2020. DOI: 10.1016/j.ajic.2020.10.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.