Медицинская библиотека · Carbohydrate polymers · 2025

Validation of the use of ToF-SIMS for analysis of glycosaminoglycans.

Milne Lorna K, Ajayakumar Arya Ajay D/O, Holyland Imogen L, Kotowska Anna M, Hogwood John, Gray Elaine, Mulloy Barbara, Merry Catherine L R, Hook Andrew L

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Glycosaminoglycans (GAGs) have a range of biological roles and are of particular interest for their pharmaceutical efficacy and their potential as biomarkers or drug targets. Heparin, used globally as an anticoagulant and an antithrombotic, is predominantly derived from porcine sources but bovine and ovine sources are increasingly being considered to reduce the substantial risk of reliance on a single animal species. However, high sensitivity chemical discrimination of heparins from different species is a significant analytical challenge. In this study ToF-SIMS analysis of GAGs is investigated as a methodology to achieve specific chemical discrimination between GAGs of different types and heparins from different animal sources. The ToF-SIMS data acquisition is relatively fast (≈1 min per sample) and requires minimal sample amounts (75 pg of sample analysed). Multivariate analysis (MVA) models enabled high selectivity between GAG type and animal source of heparin, and for the high sensitivity detection of GAG-contaminants within porcine derived heparin. Contaminants are detected down to 0.001 wt%, with the exception of ovine derived heparin where differences could be detected to 0.01 wt%. Assessments of specificity, precision, robustness and quantification limits are conducted to validate the approach for heparin analysis.

Для цитирования: Milne Lorna K, Ajayakumar Arya Ajay D/O, Holyland Imogen L, Kotowska Anna M, Hogwood John, Gray Elaine, Mulloy Barbara, Merry Catherine L R, Hook Andrew L. Validation of the use of ToF-SIMS for analysis of glycosaminoglycans.. Carbohydrate polymers. 2025. DOI: 10.1016/j.carbpol.2025.124415.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.