m+Medelevator.RU
← Поиск публикаций
Infection control and hospital epidemiology · 2025

Efficacy of a foamed disinfectant in reducing pathogen contamination in renovated inpatient in-room sinks: a randomized controlled trial.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Warren Bobby Glenn, Graves Amanda M, Fils-Aime Guerbine, Barrett Aaron, Mamikunian Isadora, Gunsch Claudia, Smith Becky A, Anderson Deverick J

Аннотация

BACKGROUND: Hospital sinks are reservoirs for epidemiologically important pathogens (EIPs), yet practical, effective strategies for sustained decontamination are lacking.

METHODS: We conducted a randomized controlled trial of 30 in-room sinks (15 intervention, 15 control) in a newly renovated hospital unit to evaluate the efficacy of a hydrogen peroxide/peracetic acid foamed disinfectant in reducing sink contamination. Intervention sinks received foamed disinfectant to sink drains three times weekly; control sinks underwent standard daily surface cleaning. Weekly sampling was performed from three sink locations (top surface, tail pipe, P-trap) over 35 weeks. The primary outcome was sink conversion events (SCEs), defined as first detection of ≥1 EIP, defined as Pseudomonas aeruginosa, Stenotrophomonas spp., or Acinetobacter spp., and ESBL-producing or carbapenem-resistant Enterobacterales, in previously negative sinks.

RESULTS: A total of 2880 samples were collected. All sinks were negative at baseline for study pathogens. Nearly all sinks (29/30) experienced an SCE during the study period. However, only 44 (9%) intervention sink samples were positive for EIPs, compared to 270 (47%) in control sinks (p < 0.00001). EIPs were recovered from 4% versus 24% of P-traps and 4% versus 39% of tail pipes; sink top/handle contamination was rare and similar (3% vs 4%). The most frequent EIPs were Acinetobacter spp. and Stenotrophomonas spp. Intervention sinks experienced a delayed time to SCE (p = 0.0001). Items were stored on/in sinks in 93% of observations.

CONCLUSION: Regular application of a foamed disinfectant reduced and delayed EIP contamination in renovated hospital sinks. Foam-based protocols may help mitigate environmental reservoirs of multidrug-resistant organisms.