MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08164622.2021.1945406

Медицинская библиотека · Clinical & experimental optometry · 2021

A comparison of subjective and objective conjunctival hyperaemia grading with AOS® Anterior software.

Walker Maria K, Tomiyama Erin S, Skidmore Kelsea V, Assaad Justina R, Ticak Anita, Richdale Kathryn

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

CLINICAL RELEVANCE: This study evaluates a commercially available conjunctival hyperaemia grading system, providing validation of an important tool for ocular surface research and clinical trials.

BACKGROUND

Bulbar conjunctival hyperaemia is a sign of ocular surface inflammation, and proper measurement is essential to clinical care and trials. The aim of this study was to assess the validity and repeatability of an objective grading system in comparison with subjective grading.

METHODS

This study was a retrospective, randomised analysis of 300 bulbar conjunctival images that were collected at an academic institution. The images used were de-identified and collected from the Keratograph K5 and Haag-Streit slitlamp. Six investigators graded the images with either a 0.1 or 0.5 unit scaling using a 0-4 Efron grading scale. Three of the investigators also imported the images into the AOS ® Anterior software and graded them objectively. All measurement techniques were assessed for repeatability and comparability to each other.

RESULTS

Mean hyperaemia with the objective system (1.1 ± 0.7) was significantly less than the subjective grading (2.0 ± 0.8) (P < 0.001). Both inter- and intra-subject repeatability of the objective system (0.15) was better than the subjective methods (1.70).

CONCLUSION

The results showed excellent repeatability of the AOS ® Anterior objective conjunctival hyperaemia grading software, although they were not found to be interchangeable with subjective scores. This system has value in monitoring levels of hyperaemia in contact lens wearers and patients in clinical care and research trials.

Для цитирования: Walker Maria K, Tomiyama Erin S, Skidmore Kelsea V, Assaad Justina R, Ticak Anita, Richdale Kathryn. A comparison of subjective and objective conjunctival hyperaemia grading with AOS® Anterior software.. Clinical & experimental optometry. 2021. DOI: 10.1080/08164622.2021.1945406.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.