MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-026-03709-6

Медицинская библиотека · The international journal of cardiovascular imaging · 2026

Mitral annular disjunction and mitral valve prolapse: echocardiographic-MRI insights into cardiac function.

King Max D, Peters Andrew C, Karimi Stuart, Owen Alyson N, Sundaram Baskaran, Pavri Behzad B

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Mitral annular disjunction (MAD) may accompany mitral valve prolapse (MVP) and is linked to ventricular arrhythmias. Its impact on global cardiac performance (specifically cardiac index (CI) and output (CO)), remains incompletely defined. Cardiac MRI (CMR) allows precise measurement of MAD, assessment of mitral annular dynamics, and detection of myocardial fibrosis via late gadolinium enhancement (LGE). We investigated both CMR and TTE metrics in patients with varying degrees of MAD compared to MVP-only.

METHODS AND

RESULTS

Fifty-six patients who underwent CMR and TTE (mean age 61, 33 female) were divided into MAD ≥2 mm and MVP (the "MAD + MVP" group, n = 41) or MVP-only (n = 15). MAD was classified as <5 mm, ≥5 mm, and ≥ 10 mm in peak systole after excluding pseudo-MAD. LV volume, stroke volume, ejection fraction, cardiac output (CO), cardiac index (CI), mitral regurgitation (MR), and LGE were assessed. Any MAD was associated with lower CI versus MVP-only (p = 0.03). MAD ≥5 mm and MAD ≥ 10 mm showed reduced CO (p = 0.04 and 0.04, respectively) and CI (p = 0.04 and 0.03, respectively) versus MVP-only. LGE was more frequent in MAD ≥ 10 mm than in MAD < 10 mm (p = 0.028). MR incidence, volume, or fraction did not differ across groups. TTE showed agreement with CMR in MAD detection and quantification (p = 0.269), with minimal inter-observer variability (p < 0.001).

CONCLUSION

MAD is associated with impaired cardiac performance independent of MR and with increased myocardial fibrosis in severe cases. These findings suggest heightened electromechanical stress in MAD compared to MVP-only, which needs to be clinically correlated. TTE reliably detects and quantifies MAD, supporting its use alongside CMR for assessment of MAD.

Для цитирования: King Max D, Peters Andrew C, Karimi Stuart, Owen Alyson N, Sundaram Baskaran, Pavri Behzad B. Mitral annular disjunction and mitral valve prolapse: echocardiographic-MRI insights into cardiac function.. The international journal of cardiovascular imaging. 2026. DOI: 10.1007/s10554-026-03709-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.