MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40001-022-00903-9

Медицинская библиотека · European journal of medical research · 2022

Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone: a biomechanical study.

Seggewiss Jana, Nicolini Luis Fernando, Lichte Philipp, Greven Johannes, Ribeiro Marx, Prescher Andreas, Michalik Roman, Herren Christian, Kobbe Philipp, Hildebrand Frank, Pishnamaz Miguel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The surgical treatment of inferior patellar pole fractures can be a challenge, especially in geriatric patients, who are particularly frequently affected by osteoporosis. The objective of this biomechanical study was to compare the performance of suture anchor and transosseous suture fixation in fractures of the inferior patellar pole in context of bone mineral density.

METHODS

Twelve fresh-frozen human cadaveric knees received a transverse osteotomy, simulating an AO/OTA 34C1.3 inferior pole fracture of the patella. These fractures were fixated with either suture anchors (SA; Corkscrew® FT 4.5 mm) or transosseous suture (TS; #2 FiberWire®). Cyclic loading tests were performed by pulling the quadriceps tendon against gravity from 90° flexion to almost full extension (5°) for 1000 cycles. Motion and fracture gap displacement were tracked until failure occurred. Subsequently, loading to failure tests followed. Differences between groups were compared using unpaired t-tests, and correlations were calculated with Pearson's correlation coefficient.

RESULTS

The suture anchor group showed significantly fewer cycles to failure than the transosseous suture group (SA: 539.0 ± 465.6 cycles, TS: 1000 ± 0 cycles, P = 0.04). Bone mineral density correlated positively with cycles to failure in the suture anchor group (Pearson's r = 0.60, P = 0.02). No differences in fracture gap displacement could be proven after 100 cycles (SA: 4.1 ± 2.6 mm, TS: 6.5 ± 2.6 mm, P = 0.19); 500 cycles (SA: 6.4 ± 6.1 mm, TS: 9.6 ± 3.8 mm, P = 0.39); and 1000 cycles (SA: 4.0 ± 0.4 mm, TS: 11.0 ± 4.5 mm, P = 0.08). Furthermore, the mean destructive load to failure in the suture anchor group was also significantly lower than in the transosseous suture group (SA: 422.4 ± 212.2 N, TS: 825.7 ± 189.3 N, P = 0.04).

CONCLUSIONS

Suture anchors may be a viable alternative to transosseous suture in younger patients for clinical advantages, but in osteoporotic bone, the more stable osteosynthesis with transosseous suture continues to prove superior. Therefore, trauma surgeons might consider the use of transosseous suture in elderly patients, especially in those presenting with low bone mineral density values.

Для цитирования: Seggewiss Jana, Nicolini Luis Fernando, Lichte Philipp, Greven Johannes, Ribeiro Marx, Prescher Andreas, Michalik Roman, Herren Christian, Kobbe Philipp, Hildebrand Frank, Pishnamaz Miguel. Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone: a biomechanical study.. European journal of medical research. 2022. DOI: 10.1186/s40001-022-00903-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.