BACKGROUND

Screening for IgA deficiency in patients with coeliac disease is essential because of the increased incidence of IgA deficiency associated with the disease, which usually relies on the estimation of IgA levels in each case.

AIM: To devise a method of excluding IgA deficiency without measuring total serum IgA in each case.

MATERIALS AND

METHODS

The optical density readings on enzyme-linked immunosorbent assay (ELISA) of 608 routine samples received for tissue transglutaminase (TTG) antibody testing for coeliac disease were compared with their total IgA concentrations. Dilution experiments were also carried out to ensure linear relationships between optical density on ELISA and IgA concentrations and to compare the sensitivities for TTG and endomysium antibodies in TTG-positive samples.

RESULTS AND DISCUSSION: A clear relationship was shown between total IgA concentration and TTG optical density readings by ELISA. To ensure a positive TTG result if antibodies are present, it was possible to recommend an optical density level above which all samples have sufficient IgA. Samples with optical density <0.05 should be investigated further by estimating total IgA and, if low, samples should be subjected to immunofluorescence microscopy testing for IgA and IgG endomysium antibodies.

CONCLUSIONS

An easier, more cost-effective and practical way of excluding IgA deficiency in the investigation on coeliac disease is reported.

Для цитирования: Sinclair D, Saas M, Turk A, Goble M, Kerr D. Do we need to measure total serum IgA to exclude IgA deficiency in coeliac disease?. Journal of clinical pathology. 2006. DOI: 10.1136/jcp.2005.031864.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.