MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2022.08.002

Медицинская библиотека · The Journal of hand surgery · 2022

Effects of a Q Suture Technique as a Core Suture on Resistance to Gap Formation and Tensile Strength in an Ex Vivo Porcine Flexor Tendon Model.

Wu Ya Fang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The Q suture has been reported to be an effective alternative to conventional peripheral sutures in tendon repair. Whether the Q method can be used as a core suture rather than a peripheral suture by adjusting the purchase length is unknown. We tested a double Q suture technique with variable purchase length and studied its effects on gap formation and tensile strength using an ex vivo model.

METHODS

Forty pig flexor tendons were repaired using the double Q sutures with purchase lengths of 2, 4, 6, and 8 mm. Twenty tendons repaired using the double Tsuge and double Kessler sutures with an 8-mm purchase length were used as controls. The tendons were subjected to cyclic loading and load-to-failure. The number of tendons that formed an initial or 2-mm gap between the tendon ends, gap distance at the repair site, stiffness, and ultimate strength were recorded.

RESULTS

During cyclic loading, the double Q suture with a 4-8-mm purchase had fewer tendons form an initial or 2-mm gap and a smaller gap size at the repair site than the Tsuge and Kessler sutures. The stiffness of the double Q suture with a 6-8-mm purchase length and Tsuge suture was greater than those of the double Kessler suture. The double Q suture with a 2-mm purchase length had smaller ultimate strength than the other sutures.

CONCLUSIONS

The Q suture may be an effective tendon repair method whose role can be converted between peripheral and core sutures via adjusting the suture purchase length. With an optimal suture length of 4-6 mm, the double Q method had tensile resistance superior to 4-strand core sutures.

CLINICAL RELEVANCE: The double Q suture may be a viable option as a core suture in flexor tendon repair when the purchase length is appropriately adjusted.

Для цитирования: Wu Ya Fang. Effects of a Q Suture Technique as a Core Suture on Resistance to Gap Formation and Tensile Strength in an Ex Vivo Porcine Flexor Tendon Model.. The Journal of hand surgery. 2022. DOI: 10.1016/j.jhsa.2022.08.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.