Most of the options available to treat distal clavicle fractures involve hardware-related complications and high failure rates. This study aims to determine the outcome of distal clavicle fractures treated by a technique that combines biological reconstruction of the coracoclavicular ligament with semitendinosus autograft with reinforced fibrous tissue tapes. In this retrospective study, 8 patients with displaced distal third clavicle fracture cho's IIB or II C were operated on with the described surgical technique between 2018 and 2021. The results were assessed by comparing the preoperative Constant Murley score and the postoperative DASH score. In addition to these variables, several other variables were also assessed, such as the coracoclavicular distance, the time until union, and all intraoperative and postoperative complications. The study included eight patients with an average age of 36.5 years, and the average time from surgery to recovery was five days. According to Cho's classification, all eight patients achieved radiographic union within 89 days. Of the eight cases, six were classified as II C and two as II B. The follow-up period was an average of 13 months. During the postoperative period, the Constant Murley score score increased from 22.2 preoperatively to 92.2 postoperatively. The mean DASH score was 89.6, and the mean postoperative DASH score was 7.75. In terms of the coracoclavicular distance, the mean preoperative was 20.2 mm, and the mean postoperative was 10.3 mm. One patient experienced a minor wound complication after surgery, treated with secondary suturing after the operation. No intraoperative complications occurred. There was no donor site morbidity observed in the patients. It has been demonstrated that the use of this technique in displaced unstable distal clavicle fractures using a fiber tape and a semitendinosus autograft results in a satisfactory union and excellent clinical outcomes with very few complications.

Для цитирования: Yadav Amit Kumar, Panchal Sameer, Gawhale Sangeet, Ks Akshay, Tiwari Anjali, Modi Nihar. Biological Reconstruction of the Coracoclavicular Ligament with Semitendinosus Autograft and Repair of Distal Clavicle Fractures.. Techniques in hand & upper extremity surgery. 2023. DOI: 10.1097/bth.0000000000000410.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.