MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.asmr.2022.05.003

Медицинская библиотека · Arthroscopy, sports medicine, and rehabilitation · 2022

Interference Screws Are Biomechanically Superior to Suture Anchors for Medial Patellofemoral Ligament Reconstruction: A Systematic Review and Meta-Analysis.

Sequeira Sean B, Imbergamo Casey, Gould Heath P

СтатьяОбзорПеревод пока не подготовлен

Аннотация

PURPOSE: To systematically review the literature to evaluate the biomechanical properties of the interference screw (IS) versus suture anchor (SA) techniques for patellar and femoral fixation of medial patellofemoral ligament (MPFL) reconstruction.

METHODS

A systematic review was performed by searching PubMed, the Cochrane library, and Embase using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify studies that analyzed the biomechanical properties of IS and SA techniques for MPFL reconstruction. The search phrase implemented was "medial patellofemoral ligament reconstruction biomechanics." Evaluated outcomes included ultimate load to failure (N), stiffness (N/mm), and mode of failure. Forest plots were created for statistical analysis and heterogeneity was assessed via I 2 statistic.

RESULTS

Six studies met inclusion criteria, including a total of 108 cadaveric specimens, for MPFL patellar fixation, and 3 studies met inclusion criteria, including a total of 50 cadaveric specimens, for MPFL femoral fixation. Pooled analysis from 5 studies reporting on stiffness for MPFL patellar fixation revealed a statistically significant difference in favor of IS compared with SA (P = .007). Pooled analysis from 3 studies reporting on ultimate load to failure of femoral fixation revealed a statistically significant difference in favor of IS compared with SA (P = .043).

CONCLUSIONS

The use of IS was associated with a greater stiffness compared with the use of SA in MPFL patellar fixation, but there was no difference in load to failure between IS and SA. The use of IS was associated with a greater load to failure compared with the use of SA in MPFL femoral fixation, but there was no difference in stiffness between IS and SA.

CLINICAL RELEVANCE: There have been multiple individual biomechanical studies conducted comparing IS and SA fixation for MPFL patellar and femoral fixation; however, they have yielded conflicting results, with small sample sizes. Pooling the data from these studies in a meta-analysis may allow for more meaningful biomechanical data to coincide with the existing, albeit scarce, clinical data, this may help to inform clinical decision making for surgeons managing these injuries.

Другие публикации по теме

Для цитирования: Sequeira Sean B, Imbergamo Casey, Gould Heath P. Interference Screws Are Biomechanically Superior to Suture Anchors for Medial Patellofemoral Ligament Reconstruction: A Systematic Review and Meta-Analysis.. Arthroscopy, sports medicine, and rehabilitation. 2022. DOI: 10.1016/j.asmr.2022.05.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.