MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00365520410008051

Медицинская библиотека · Scandinavian journal of gastroenterology · 2004

IgA antibodies to human tissue transglutaminase: audit of routine practice confirms high diagnostic accuracy.

Hill P G, Forsyth J M, Semeraro D, Holmes G K T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The diagnostic accuracy of IgA tissue transglutaminase antibodies (TGA) for coeliac disease (CD) has been assessed following the introduction of the test into routine practice in 2002.

METHODS

Specificity was assessed in serum samples received from 1554 adults for routine coeliac serology. The population for assessing sensitivity was 75 consecutive new adult diagnoses of CD. TGA was measured by enzyme-linked immunoassay using human tissue transglutaminase as antigen. Concordance between TGA and endomysial antibody (EMA) was also assessed.

RESULTS

The prevalence of new diagnoses of CD in the population tested was 2.8% with similar proportions of new diagnoses in males and females. The positive predictive values at a cut-off of 3 units/mL were 0.77 for samples from Primary Care and 0.92 for samples from Hospital sources, with a sensitivity of 92%. At TGA <3 units/mL, EMA was usually negative; when TGA was >4.9 units/mL, EMA was rarely negative.

CONCLUSIONS

We have assessed the role of TGA in routine clinical practice and confirmed high diagnostic accuracy. Sensitivity (92%) is identical to the sensitivity for EMA. IgA deficiency should be excluded in samples showing low absorbance readings in the TGA assay and interference from monoclonal and polyclonal IgA should be excluded in samples with slightly raised TGA levels and negative EMA. TGA is recommended as the first-line serological test for coeliac disease.

Для цитирования: Hill P G, Forsyth J M, Semeraro D, Holmes G K T. IgA antibodies to human tissue transglutaminase: audit of routine practice confirms high diagnostic accuracy.. Scandinavian journal of gastroenterology. 2004. DOI: 10.1080/00365520410008051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.