DOI 10.1111/j.1440-1746.2006.04764.x
Endoscopic balloon dilatation of intestinal strictures in Crohn's disease: safe alternative to surgery.
Аннотация
BACKGROUND AND AIM: Endoscopic balloon dilatation (EBD), a non-surgical treatment option for intestinal strictures in Crohn's disease, appears to be applied infrequently, possibly due to the perceived risk of perforation and early recurrence. This study aimed to determine the outcomes of EBD by a single endoscopist using a defined technique.
METHODS
The records of all patients with Crohn's disease in whom EBD was attempted over a 12-year period were examined to determine the rate of technical success, complications and outcome. A stricture was defined as that which prevented passage of the 14 mm diameter colonoscope. Technical success was defined as the ability to traverse the stricture postdilatation. Patients were selected on the colonoscopic appearance of the stricture and dilatation was performed using through-the-endoscope balloons. Antibiotics were given during and for 7 days postdilatation.
RESULTS
EBD was attempted on 83 strictures (31 anastomotic and 52 primary) in 37 patients (15 males) and was successful in 75 (90%) of 31 patients. A single dilatation only was required in 21 patients who had a median follow-up of 20 months (range 6-122 months). Recurrent symptomatic stricture requiring dilatation (eight patients) or surgery (two patients) occurred 8 (1-112) months after the initial dilatation. The only complication occurred in one patient where an intra-abdominal fistula and abscess were probably related to the dilatation.
CONCLUSION
EBD of intestinal strictures associated with Crohn's disease has a low complication rate and leads to prolonged clinical benefit. It should be considered as a real alternative to surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.