This study examined the contact surface area in the coupling of a class II amalgam restoration with another class II amalgam restoration or with a stainless steel or nickel-chrome crown in 1% NaCl solution. The characterization of interfaces was carried out by using SEM and EDX microanalysis. The results indicate that the coupling of an amalgam-stainless steel crown and an amalgam-inconel crown in NaCl solution forms a deposit on the crown surfaces. This deposit contains all the constituents of corrodible phases of amalgam, including Zn. If amalgam restorations in adjoining teeth are contemplated, non-Zn-containing amalgam alloys of the same composition should be considered.

Для цитирования: Schimelmitz H, Bapna M S, Punwani I, Ashrafi S H, Anderson A W. Interface corrosion in amalgam-to-amalgam and amalgam-to-nonprecious metal crown couplings.. The Journal of prosthetic dentistry. 1986. DOI: 10.1016/0022-3913(86)90340-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.