MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s123640

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2017

Early experiences of planning stereotactic radiosurgery using 3D printed models of eyes with uveal melanomas.

Furdová Alena, Sramka Miron, Thurzo Andrej, Furdová Adriana

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery.

METHODS

The software for segmentation (3D Slicer) created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D®) and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid.

RESULTS

In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient's eye with intraocular tumor. In the period 2001-2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma) were treated. The median tumor volume was 0.5 cm3 (0.2-1.6 cm3). The radiation dose was 35.0 Gy by 99% of dose volume histogram.

CONCLUSION

The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures.

Для цитирования: Furdová Alena, Sramka Miron, Thurzo Andrej, Furdová Adriana. Early experiences of planning stereotactic radiosurgery using 3D printed models of eyes with uveal melanomas.. Clinical ophthalmology (Auckland, N.Z.). 2017. DOI: 10.2147/opth.s123640.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.