MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.16-19558

Медицинская библиотека · Investigative ophthalmology & visual science · 2016

Quantitative Measurements of the Ciliary Body in Eyes With Acute Primary-Angle Closure.

Wang Zhonghao, Chung Chuchen, Lin Jialiu, Xu Jianan, Huang Jingjing

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the structural differences of the ciliary body in patients with acute primary-angle closure (APAC) and normal subjects.

METHODS

Forty-four patients with APAC in one eye and 25 eyes from 25 age-matched normal subjects were consecutively recruited. A-scan ultrasound and ultrasound biomicroscopy (UBM) measurements were performed. Ciliary body parameters including maximum ciliary body thickness (CBTmax), ciliary body thickness at point of the scleral spur (CBT0) and 1000 μm from the scleral spur (CBT1000), anterior placement of ciliary body (APCB), and trabecular-ciliary process angle (TCA), as well as biometric measurements, were measured.

RESULTS

Average CBTmax was 0.894 ± 0.114, 0.967 ± 0.110, and 1.053 ± 0.103 mm in eyes with APAC, their fellow eyes, and normal eyes, respectively. Average CBT1000 was 0.616 ± 0.111, 0.631 ± 0.088, and 0.842 ± 0.118 mm, respectively. Average TCA was 48.10 ± 13.26°, 50.60 ± 9.08°, and 87.11 ± 20.71°, respectively. CBTmax and CBT0 were thinner in eyes with APAC compared with their fellow eyes (P = 0.002, P < 0.001). In addition, CBTmax, CBT1000, and TCA were smaller whereas APCB was larger in the fellow eyes of APAC patients compared with normal eyes (P = 0.002, P < 0.001, P < 0.001, P < 0.001). The anterior chamber depth (ACD) was smaller whereas lens thickness (LT) was larger in eyes with APAC compared with their fellow eyes (P < 0.001, P = 0.036). Smaller ACD and axial length and larger LT and lens vault were found in the fellow eyes of APAC patients compared with normal eyes (P < 0.001, P < 0.001, P = 0.015, P = 0.001).

CONCLUSIONS

Ciliary bodies were thinner and more anteriorly rotated in eyes with APAC as well as in their fellow eyes. Further studies are needed to elucidate the relationship between ciliary body parameters and mechanism of APAC.

Для цитирования: Wang Zhonghao, Chung Chuchen, Lin Jialiu, Xu Jianan, Huang Jingjing. Quantitative Measurements of the Ciliary Body in Eyes With Acute Primary-Angle Closure.. Investigative ophthalmology & visual science. 2016. DOI: 10.1167/iovs.16-19558.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.