MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-018-1437-7

Медицинская библиотека · The international journal of cardiovascular imaging · 2018

A serial 3- and 9-year optical coherence tomography assessment of vascular healing response to sirolimus- and paclitaxel-eluting stents.

Tomaniak Mariusz, Kołtowski Łukasz, Pietrasik Arkadiusz, Rdzanek Adam, Jąkała Jacek, Proniewska Klaudia, Malinowski Krzysztof, Mazurek Tomasz, Filipiak Krzysztof J, Brugaletta Salvatore, Opolski Grzegorz, Kochman Janusz

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Early-generation drug-eluting stents (DES) have been demonstrated to delay vascular healing. Limited optical coherence tomography (OCT) data on the very long-term neointimal response after DES implantation are available. The aim of this study was a serial OCT assessment of neointimal thickness, stent strut coverage, malapposition, and protrusion as markers of neointimal response at 3 and 9 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). In this single-centre, longitudinal study consecutive patients undergoing elective PCI with SES or PES were included. OCT analysis was performed after 3 and 9 years by the independent core laboratory. A total of 22 subjects (8 SES and 14 PES) underwent an OCT assessment at 3 and 9 years post index procedure. The lumen, neointimal and malapposition area and the neointimal thickness (SES ∆50 µm, p = 0.195, PES ∆10 µm, p = 0.951) did not change significantly over the 6 year follow-up. No differences in the incidence of uncovered, malapposed or protruding struts were found in each type of stent. At 3 and 9 years after PCI, implantation of early-generation SES and PES may be associated with similar neointimal thickness, strut coverage, malapposition and protrusion, as assessed by serial OCT examination among patients with uneventful follow-up at 3 years post procedure. The small size of the study warrants judicious interpretation of our results and confirmation in larger multimodality imaging studies, including patients treated with contemporary stent platforms.

Для цитирования: Tomaniak Mariusz, Kołtowski Łukasz, Pietrasik Arkadiusz, Rdzanek Adam, Jąkała Jacek, Proniewska Klaudia, Malinowski Krzysztof, Mazurek Tomasz, Filipiak Krzysztof J, Brugaletta Salvatore, Opolski Grzegorz, Kochman Janusz. A serial 3- and 9-year optical coherence tomography assessment of vascular healing response to sirolimus- and paclitaxel-eluting stents.. The international journal of cardiovascular imaging. 2018. DOI: 10.1007/s10554-018-1437-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.