Impact of Patient-Prosthesis Mismatch following Aortic Valve Replacement on Long-Term Survival and Quality of Life.

Hoffmann Grischa, Abraham-Westphal Selam, Attmann Tim, Frank Derk, Lutter Georg, Cremer Jochen, Petzina Rainer

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The impact of patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) on long-term survival and quality of life (QoL) remains controversial. The objective of this study was to evaluate the impact of PPM on long-term survival and QoL in a large cohort of patients treated with isolated stented biological AVR in a single-center experience.

METHODS

We analyzed data of 632 consecutive patients following isolated stented biological AVR between 2007 and 2012 at our institution. We evaluated the QoL (393 evaluable patients) using the Short Form 12-item Health Survey (SF-12) questionnaire via telephone call and the impact of PPM on long-term survival (533 evaluable patients) by Kaplan-Meier's estimate.

RESULTS

Severe PPM (<0.65 cm2/m2) had a negative impact on physical component summary (PCS) score (SF-12) compared with patients with moderate or no PPM (p = 0.014), while the mental component summary (MCS) score (SF-12) was not affected by the degree of PPM (p = 0.133). Long-term survival was not different among the three different PPM groups investigated (p = 0.75).

CONCLUSION

Severity of PPM demonstrated no influence on long-term survival and MCS score (SF-12), but it was associated with a lower PCS score (SF-12) in patients with severe PPM.

Для цитирования: Hoffmann Grischa, Abraham-Westphal Selam, Attmann Tim, Frank Derk, Lutter Georg, Cremer Jochen, Petzina Rainer. Impact of Patient-Prosthesis Mismatch following Aortic Valve Replacement on Long-Term Survival and Quality of Life.. The Thoracic and cardiovascular surgeon. 2018. DOI: 10.1055/s-0038-1666973.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.