MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2017-017231

Медицинская библиотека · BMJ open · 2018

Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials.

Cai Jin-Zan, Zhu Yong-Xiang, Wang Xin-Yu, Bourantas Christos V, Iqbal Javaid, Zhu Hao, Cummins Paul, Dong Sheng-Jie, Mathur Anthony, Zhang Yao-Jun

Сравнительное исследованиеСтатьяМетаанализПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The study sought to compare angiographic and clinical outcomes of new-generation drug-eluting stents (DES) versus drug-coated balloon (DCB) in patients with coronary in-stent restenosis (ISR).

DESIGN

Meta-analysis using data from randomised trial found by searches on PubMed, the Cochrane Library, ClinicalTrials.gov and websites of major cardiovascular congresses.

SETTING

Only randomised trials comparing DES with DCB were included.

PARTICIPANTS

Patients with ISR in the included trials.

INTERVENTIONS: New-generation DES versus DCB.

OUTCOMES: The angiographic and clinical outcomes including cardiac death, all-cause death, myocardial infarction, target lesion revascularisation (TLR), target vessel revascularisation (TVR), major adverse cardiac events (MACE) and stent thrombosis were investigated.

RESULTS

Five trials including 913 patients were eligible and included. Pooled analysis in angiographic results identified that new-generation DES were associated with higher acute luminal gain (-0.31 mm, 95% CI -0.42 to -0.20, P<0.001) and lower per cent diameter stenosis (risk ratio (RR): 0.28, 95% CI 0.02 to 0.55, P=0.04). DES significantly reduced the risk of TLR (RR: 1.96, 95% CI 1.17 to 3.28, P=0.01) compared with DCB; however, there was no statistical differences for MACE (RR: 1.21, 95% CI 0.67 to 2.17, P=0.53), myocardial infarction (RR: 1.16, 95% CI 0.55 to 2.48, P=0.69) and cardiac death (RR: 1.80, 95% CI 0.60 to 5.39, P=0.29).

CONCLUSIONS

Interventions with new-generation DES appear to be associated with significant reduction in per cent diameter stenosis and TLR at short-term follow-up, but had similar MACE, myocardial infarction and cardiac death for patients with coronary ISR compared with DCB. Appropriately powered studies with longer term follow-up are warranted to confirm these findings.

Для цитирования: Cai Jin-Zan, Zhu Yong-Xiang, Wang Xin-Yu, Bourantas Christos V, Iqbal Javaid, Zhu Hao, Cummins Paul, Dong Sheng-Jie, Mathur Anthony, Zhang Yao-Jun. Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials.. BMJ open. 2018. DOI: 10.1136/bmjopen-2017-017231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.