MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.117.005409

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2018

Transvenous Lead Extraction in Adults With Congenital Heart Disease: Insights From a 20-Year Single-Center Experience.

Gourraud Jean-Baptiste, Chaix Marie-A, Shohoudi Azadeh, Pagé Pierre, Dubuc Marc, Thibault Bernard, Poirier Nancy C, Dore Annie, Marcotte François, Mongeon François-Pierre, Asgar Anita W, Ibrahim Réda, Khairy Paul, Mondésert Blandine

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Safety and feasibility data on transvenous lead extraction (TLE) in the challenging population of adults with congenital heart disease (A-CHD) are limited. Herein, we report the results of TLE in A-CHD during a 20-year period.

METHODS AND

RESULTS

All consecutive TLE procedures in A-CHD were included in a monocentric prospective registry from 1996. A total of 121 leads were extracted in 49 A-CHD (median age, 38 years; 51% men) during 71 TLE procedures. Twenty-four (49%) patients had transposition of the great arteries. Main indications for extraction were infection in 34 (48%) and lead failure in 22 (31%). A laser sheath was required for 56 (46%) leads and a femoral approach for 10 (8%). Complete TLE was achieved for 111 leads (92%). In multivariable analysis, lead duration (odds ratio, 1.02; 95% confidence interval, 1.00-1.04; P<0.01) and number of previous cardiac surgeries (odds ratio, 2.65; 95% confidence interval, 1.52-4.67; P<0.01) were predictive of TLE failure. No perioperative death or pericardial effusion was observed. Subpulmonary atrioventricular valve regurgitation increased in 8 patients (5 with transposition of the great arteries) and was independently associated with an implantable cardioverter defibrillator lead (odds ratio, 9.69; 95% confidence interval, 1.31-71.64; P=0.03) and valvular vegetation (odds ratio, 7.29; 95% confidence interval, 1.32-40.51; P=0.02). After a median of 54 (19-134) months of follow-up after the first TLE, 3 deaths occurred independently from lead management.

CONCLUSIONS

Despite complex anatomic issues, TLE can be achieved successfully in most A-CHD using advanced extraction techniques. Subpulmonary atrioventricular valve regurgitation is a prevalent complication, particularly in patients with transposition of the great arteries.

Для цитирования: Gourraud Jean-Baptiste, Chaix Marie-A, Shohoudi Azadeh, Pagé Pierre, Dubuc Marc, Thibault Bernard, Poirier Nancy C, Dore Annie, Marcotte François, Mongeon François-Pierre, Asgar Anita W, Ibrahim Réda, Khairy Paul, Mondésert Blandine. Transvenous Lead Extraction in Adults With Congenital Heart Disease: Insights From a 20-Year Single-Center Experience.. Circulation. Arrhythmia and electrophysiology. 2018. DOI: 10.1161/circep.117.005409.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.