MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13300

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2018

Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infection.

Greenspon Arnold J, Eby Elizabeth L, Petrilla Allison A, Sohail M Rizwan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac implantable electronic device (CIED) infection is a serious adverse event, but there are limited contemporary real-world data on treatment pathways and associated costs in the Medicare population following diagnosis of CIED infection. Hence, this study evaluates postinfection treatment pathways and associated healthcare expenditures and mortality among Medicare fee-for-service beneficiaries with CIED infection.

METHODS

Retrospective cohort analysis of 5,401 beneficiaries who developed a device-related infection in the year following implantation/upgraded CIED (1/1/2010-12/31/2012). Patients were followed-up to 12 months/death following diagnosis of infection and were divided into mutually exclusive groups based on whether they underwent CIED system removal (Group I), or no CIED system intervention (Group II; IIA with or IIB without infection hospitalization). All-cause healthcare resource utilization/expenditures were also measured.

RESULTS

In the year following infection, 64.1% of patients underwent device extraction, of who 2,109 (39.0%) had their device replaced (Group IA) and 1,355 (25.1%) had their device extracted without replacement (Group IB); 62.2% of patients were hospitalized and 25.3% of patients died. Mean Medicare payments-per-patient for facility-based services by group were: IA = $62,638 (standard deviation [SD]: $46,830), IB = $50,079 (SD: $45,006), IIA = $77,397 (SD: $79,130), and IIB = $22,856 (SD: $31,167).

CONCLUSIONS

Hospitalizations were the largest cost driver; infection-related costs, including cost of extraction/replacement, accounted for >50% of expenditures for patients with surgical/hospital intervention. Management of CIED infection in Medicare beneficiaries is associated with high healthcare expenditures in the year following infection. Additional measures to prevent device infection are needed to improve the outcomes and reduce costs in these patients.

Для цитирования: Greenspon Arnold J, Eby Elizabeth L, Petrilla Allison A, Sohail M Rizwan. Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infection.. Pacing and clinical electrophysiology : PACE. 2018. DOI: 10.1111/pace.13300.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.