MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2017.11.066

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2018

New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.

Benedetto Umberto, Taggart David P, Sousa-Uva Miguel, Biondi-Zoccai Giuseppe, Di Franco Antonino, Ohmes Lucas B, Rahouma Mohamed, Kamel Mohamed, Caputo Massimo, Girardi Leonard N, Angelini Gianni D, Gaudino Mario

СтатьяСистематический обзорNetwork Meta-AnalysisПеревод пока не подготовлен

Аннотация

BACKGROUND

With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials.

METHODS

All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization.

RESULTS

Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2.1-14), whereas first-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) and second-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) were comparable.

CONCLUSIONS

The introduction of new-generation drug-eluting stents did not translate into better outcomes for percutaneous coronary intervention when compared with coronary artery bypass grafting.

Для цитирования: Benedetto Umberto, Taggart David P, Sousa-Uva Miguel, Biondi-Zoccai Giuseppe, Di Franco Antonino, Ohmes Lucas B, Rahouma Mohamed, Kamel Mohamed, Caputo Massimo, Girardi Leonard N, Angelini Gianni D, Gaudino Mario. New-generation stents compared with coronary bypass surgery for unprotected left main disease: A word of caution.. The Journal of thoracic and cardiovascular surgery. 2018. DOI: 10.1016/j.jtcvs.2017.11.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.