Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020

Tc-99m-pyrophosphate scintigraphy for the diagnosis of ATTR cardiac amyloidosis: Comparison of quantitative and semi-quantitative approaches.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Régis Claudine, Harel François, Martineau Patrick, Grégoire Jean, Abikhzer Gad, Juneau Daniel, Pelletier-Galarneau Matthieu

Аннотация

BACKGROUND: ATTR cardiac amyloidosis (CA) can be diagnosed with Tc-99m-PYP scintigraphy. There are two recommended interpretative approaches: the quantitative heart-to-contralateral lung ratio (H/CL) at 1 hour and the semi-quantitative visual system at 3 hours. This study's aim was to compare both approaches and to apply the semi-quantitative method at 1 hour.

METHODS: Tc-99m-PYP scans of 122 consecutive subjects were reviewed using both approaches. On 1 hour planar images, regions of interest were drawn over the heart and contralateral chest to determine H/CL. Myocardial uptake was graded on 1 and 3 hour SPECT images according to the semi-quantitative method. Concordance was examined using kappa statistics.

RESULTS: 31, 10, and 81 studies were positive, negative, and equivocal, respectively, for ATTR-CA using the H/CL approach. Using the grading system, 35, 77, and 10 scans were positive, negative, and equivocal, respectively. The quantitative approach led to a significantly higher proportion of equivocal studies compared to the semi-quantitative approach (P < .0001). These approaches yielded discordant results in 2 subjects; biopsy results were concordant with SPECT grade. 1 and 3 hour SPECT grades provided concordant result in 99% of cases.

CONCLUSIONS: The H/CL approach resulted in a high proportion of equivocal studies. Using SPECT imaging, the semi-quantitative approach minimized this proportion and showed high concordance at 1 and 3 hours.