DOI 10.1161/circimaging.119.010249

Медицинская библиотека · Circulation. Cardiovascular imaging · 2020

Efficient 1-Hour Technetium-99 m Pyrophosphate Imaging Protocol for the Diagnosis of Transthyretin Cardiac Amyloidosis.

Masri Ahmad, Bukhari Syed, Ahmad Shahzad, Nieves Ricardo, Eisele Yvonne S, Follansbee William, Brownell Amy, Wong Timothy C, Schelbert Erik, Soman Prem

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Technetium-99 m pyrophosphate protocols for transthyretin cardiac amyloidosis diagnosis have variably used 1- and 3-hour imaging time points. We investigated whether imaging at 1 hour with superior efficiency had comparable diagnostic accuracy as 3-hour imaging.

METHODS

This is a registry analysis of patients with suspected transthyretin cardiac amyloidosis referred for technetium-99 m pyrophosphate at a single tertiary center from June 2015 through January 2019. Patients underwent planar and single-photon emission computed tomography (SPECT) imaging at 1 and 3 hours. A positive Tc-99m pyrophosphate study was defined by the presence of diffuse myocardial tracer uptake on SPECT. For planar imaging, visual semiquantitative (grades 0-3, ≥2 considered positive) and quantitative heart to contralateral ratios (≥1.5 considered positive) were used.

RESULTS

Two hundred thirty-three patients (69% men; median age, 77 [69-83] years) underwent the study protocol. There were 60 (25.8%) patients with diffuse myocardial uptake, 1 (0.4%) with regional uptake, and 172 (73.8%) with no myocardial uptake. Results of SPECT were identical at 1 and 3 hours. Planar imaging at 1 hour had 98% sensitivity and 96% specificity. Planar grade 0 uptake or heart to contralateral ratio ≤1.2 and planar grade 3 uptake or heart to contralateral ratio ≥2.0 were always associated with negative and positive SPECT, respectively. For planar grades 1 and 2 uptake and heart to contralateral ratio 1.3 to 1.9, SPECT was needed to make a diagnosis. No patient with light-chain cardiac amyloidosis had positive SPECT.

CONCLUSIONS

An efficient 1-hour technetium-99 m pyrophosphate protocol had comparable diagnostic performance to a 3-hour protocol.

Для цитирования: Masri Ahmad, Bukhari Syed, Ahmad Shahzad, Nieves Ricardo, Eisele Yvonne S, Follansbee William, Brownell Amy, Wong Timothy C, Schelbert Erik, Soman Prem. Efficient 1-Hour Technetium-99 m Pyrophosphate Imaging Protocol for the Diagnosis of Transthyretin Cardiac Amyloidosis.. Circulation. Cardiovascular imaging. 2020. DOI: 10.1161/circimaging.119.010249.