DOI 10.1097/pxr.0000000000000017
Comparison of patient-reported and functional outcomes following transition from mechanical to microprocessor knee in the low-activity user with a unilateral transfemoral amputation.
Аннотация
BACKGROUND
The Scottish Specialist Prosthetics Service has provided microprocessor knees (MPKs) through the National Health Service since 2014, predominantly to high-activity transfemoral amputations (TFAs). Benefits of MPKs to the lower-activity TFA are less established in the literature.
OBJECTIVES
This study aimed to compare patient-reported and functional measures in low-activity TFAs transitioning from a mechanical knee to a MPK.
STUDY
DESIGN
This is a retrospective cohort analysis of low-activity individuals with a unilateral TFA provided with an MPK.
METHODS
Patient-reported measures were recorded in routine clinical care before and 6 months after MPK provision. These included HR-QoL (EQ-5D-5L Health Index), Activities Balance Confidence score, Prosthetic Limb User Survey of Mobility, falls frequency, use of walking aids, and Socket Comfort Score. Functional measures included the two-minute walk test (2MWT), L-test, and Amputee Mobility Predictor score, and three-dimensional gait analysis was used to generate a Gait Profile Score (GPS). The primary outcomes were HR-QoL and GPS.
RESULTS
Forty-five participants fulfilled the inclusion criteria. Thirty-one had pre-MPK and post-MPK measures, of which 15 had three-dimensional gait analysis. The mean age (n = 31) was 60 years (SD 11), and 68% were male. HR-QoL and GPS did not significantly improve with MPK provision (p = 0.014 and p = 0.019); Amputee Mobility Predictor score, L-Test, 2MWT, falls, and Activities Balance Confidence score showed a significant improvement with MPK provision (p < 0.001).
CONCLUSIONS
Although no statistically significant change in the primary outcomes was measured, there were sufficient data to support MPK provision in low-activity prosthetic users with participants demonstrating improvements in balance, 2MWT, falls frequency, and confidence.