MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2026.100958

Медицинская библиотека · Physics and imaging in radiation oncology · 2026

Geometry-based framework for beam angle selection in proton therapy for lung cancer.

Fotiou Kyriakos, Lønne Per-Ivar, Malinen Eirik

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Proton therapy is a promising modality for treating locally advanced non-small cell lung cancer (LA-NSCLC). However, respiratory-induced intra-fractional motion can compromise tumour coverage. This work aimed to develop a method to identify proton beam angles that balance tumour coverage and organ-at-risk (OAR) sparing.

MATERIALS AND

METHODS

An open-source dataset of eleven LA-NSCLC patients with four-dimensional CT (4DCT) scans was analysed. For each gantry-couch angle, the water equivalent path length variation (ΔWEPL) and percentage irradiated volume (PIV) were calculated using in-house code to serve as metrics for tumour motion sensitivity and geometric OAR exposure. A unified risk map was constructed based on ΔWEPL and PIV, with patient-specific weighting factors and constraints to enable individualised beam selection. Subsequent single-beam treatment plans were generated on the average intensity projection CT, with the dose distribution recalculated on all breathing phases to derive ΔD95% (variability in target D95%). Pearson's correlation tested associations between ΔWEPL and ΔD95% and between PIV and OAR dose.

RESULTS

ΔWEPL correlated with target dose degradation (median r = 0.90 for ΔD95%), while PIV correlated with OAR doses (r = 0.88-0.98 across heart, lungs, and spinal cord). Risk maps identified beam angles minimising motion sensitivity while respecting OAR constraints. A three-beam patient example illustrated that clinically acceptable tumour coverage was maintained while substantially reducing lung and heart dose compared to suboptimal beam orientations.

CONCLUSIONS

Patient-specific proton beam angle selection by combining ΔWEPL and PIV into a unified risk map offers a clinically relevant strategy to improve robustness and OAR sparing for LA-NSCLC.

Для цитирования: Fotiou Kyriakos, Lønne Per-Ivar, Malinen Eirik. Geometry-based framework for beam angle selection in proton therapy for lung cancer.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.100958.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.