MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-024-01312-6

Медицинская библиотека · Journal of imaging informatics in medicine · 2024

Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy.

Koike Yuhei, Takegawa Hideki, Anetai Yusuke, Nakamura Satoaki, Yoshida Ken, Yoshida Asami, Yui Midori, Hirota Kazuki, Ueda Kenichi, Tanigawa Noboru

СтатьяПеревод пока не подготовлен

Аннотация

Cone-beam computed tomography (CBCT) is widely utilized in image-guided radiation therapy; however, its image quality is poor compared to planning CT (pCT), thus restricting its utility for adaptive radiotherapy (ART). Our objective was to enhance CBCT image quality utilizing a transformer-based deep learning model, SwinUNETR, which we compared with a conventional convolutional neural network (CNN) model, U-net. This retrospective study involved 260 patients undergoing prostate radiotherapy, with 245 patients used for training and 15 patients reserved as an independent hold-out test dataset. Employing a CycleGAN framework, we generated synthetic CT (sCT) images from CBCT images, employing SwinUNETR and U-net as generators. We evaluated sCT image quality and assessed its dosimetric impact for photon therapy through gamma analysis and dose-volume histogram (DVH) comparisons. The mean absolute error values for the CT numbers, calculated using all voxels within the patient's body contour and taking the pCT images as a reference, were 84.07, 73.49, and 64.69 Hounsfield units for CBCT, U-net, and SwinUNETR images, respectively. Gamma analysis revealed superior agreement between the dose on the pCT images and on the SwinUNETR-based sCT plans compared to those based on U-net. DVH parameters calculated on the SwinUNETR-based sCT deviated by < 1% from those in pCT plans. Our study showed that, compared to the U-net model, SwinUNETR could proficiently generate more precise sCT images from CBCT images, facilitating more accurate dose calculations. This study demonstrates the superiority of transformer-based models over conventional CNN-based approaches for CBCT-to-CT translation, contributing to the advancement of image synthesis techniques in ART.

Для цитирования: Koike Yuhei, Takegawa Hideki, Anetai Yusuke, Nakamura Satoaki, Yoshida Ken, Yoshida Asami, Yui Midori, Hirota Kazuki, Ueda Kenichi, Tanigawa Noboru. Cone-Beam CT to CT Image Translation Using a Transformer-Based Deep Learning Model for Prostate Cancer Adaptive Radiotherapy.. Journal of imaging informatics in medicine. 2024. DOI: 10.1007/s10278-024-01312-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.