An antibody-free dual-biomarker rapid enrichment workflow (AnDREW) improves the sensitivity of malaria rapid diagnostic tests.

Kantor Andrew G, Markwalter Christine F, Nourani Armin, Wright David W

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Rapid diagnostic tests (RDTs) are critical to the success of malaria elimination campaigns. These tests are rapid, user-friendly, and field-deployable to resource-limited regions. However, RDTs demonstrate poor sensitivity because they can only tolerate a small (5 μL) volume of blood, which limits the amount of protein biomarker delivered to the test. We have developed the Antibody-free Dual-biomarker Rapid Enrichment Workflow (AnDREW) for purifying histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (PLDH) from large volume (150 μL) blood samples. We used Zn(II)NTA and aptamer-conjugated magnetic beads to capture HRP2 and PLDH, respectively. Both biomarkers were then eluted into RDT-compatible volumes using ethylene diamine tetraacetic acid (EDTA). We optimized both bead conjugates individually by enzyme-linked immunosorbent assays (ELISAs) and then combined the optimized capture and elution assays for both biomarkers to produce the AnDREW. The AnDREW-enhanced RDTs exhibited a 11-fold and 9-fold improvement in analytical sensitivity for detection of HRP2 and PLDH, respectively, when compared to unenhanced RDTs. Moreover, the limit of detection for PLDH was improved 11-fold for the AnDREW-enhanced RDTs (3.80 parasites/μL) compared to unenhanced RDTs (42.31 parasites/μL). Importantly, the AnDREW utilizes a pan-specific PLDH aptamer and improves upon existing methods by eluting both biomarkers without complexed antibodies.

Для цитирования: Kantor Andrew G, Markwalter Christine F, Nourani Armin, Wright David W. An antibody-free dual-biomarker rapid enrichment workflow (AnDREW) improves the sensitivity of malaria rapid diagnostic tests.. Analytical biochemistry. 2020. DOI: 10.1016/j.ab.2020.114020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.