UNLABELLED: Fabry disease (FD) is a rare X-linked lysosomal storage disorder characterized by heterogeneous clinical manifestations. Cardiac involvement arises from progressive glycosphingolipid accumulation within cardiomyocytes, vascular endothelium, and the conduction system, resulting in left ventricular hypertrophy, conduction abnormalities, and arrhythmias. A subset of patients exhibits electrocardiographic findings that mimic acute myocardial infarction (AMI), often leading to misdiagnosis as ischemic heart disease.

CASE PRESENTATION: We describe a 62-year-old man presenting with recurrent chest pain and syncope. Initial electrocardiography demonstrated pathological Q waves and ST-segment elevation in the anterior leads. Echocardiography revealed concentric left ventricular hypertrophy. Serial cardiac biomarkers, repeat echocardiography, and coronary angiography excluded AMI. The diagnosis of FD was confirmed by markedly reduced leukocyte α-galactosidase A activity, elevated plasma lyso-Gb3 concentrations, and identification of a pathogenic hemizygous variant in the GLA gene.

CONCLUSION

In patients with unexplained left ventricular hypertrophy and "pseudo-infarction" electrocardiographic patterns, targeted evaluation for FD is warranted to prevent diagnostic delay and enable timely initiation of enzyme replacement therapy (ERT) and multidisciplinary management.

Для цитирования: Xie Jin-Mei, Li Qing, Xiao Zhi-Qiang, Zheng Zong-Jie. Case Report: Fabry disease presenting with electrocardiographic findings mimicking acute myocardial infarction: a diagnostic challenge.. Frontiers in cardiovascular medicine. 2026. DOI: 10.3389/fcvm.2026.1727546.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.