MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejvs.2015.04.035

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2015

Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.

He H, Yao K, Nie W P, Wang Z, Liang Q, Shu C, Dardik A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study evaluates the safety and efficacy of pre-placement of a distal bare stent as an adjunct to thoracic endovascular aortic repair (TEVAR) in the setting of complicated acute Stanford type B aortic dissection (cTBAD).

METHODS

The records of all patients diagnosed with cTBAD at the institution between 2010 and 2013 were reviewed. Indications for the pre-placement of a distal bare stent included symptomatic malperfusion and/or radiological evidence of true lumen collapse. Computed tomography angiography was performed post-operatively to assess aortic remodeling.

RESULTS

148 patients were treated for cTBAD: 113 patients (76.4%) were treated with standard TEVAR and 35 (23.6%) were treated by combined proximal TEVAR with pre-placement of an adjunctive distal bare stent. Primary technical success was 95.9%. The 30 day mortality rate was 4.1% and was not different between groups. The 30 day morbidity included transient renal failure (10.1%), endoleak (7.4%), and paraplegia (2.7%), and was not different between groups. The mean follow up was 10 months (range 2-12 months). No late stent complications were observed; patients with an adjunctive bare stent had less distal re-dissection (0% vs. 15%; p = .01) and fewer endovascular re-interventions (5.7% vs. 20.4%; p = .04). At 1 year, patients treated with TEVAR and an adjunctive distal bare stent had increased true lumen volume (166 vs. 110 mL; p = .022), decreased false lumen volume (60 vs. 90 mL; p = .043), and increased complete false lumen thrombosis in the thoracic (76.5% vs. 29.5%; p < .001) and abdominal (20.6% vs. 3.8%; p = .002) segments.

CONCLUSIONS

Combined pre-placement of a distal bare stent as an adjunct to proximal TEVAR to treat cTBAD restricts oversizing of the distal stent graft, reducing the potential for distal true lumen collapse and visceral malperfusion, and improving remodeling of the dissected thoracic aorta. Long-term follow up and prospective studies are needed to assess the overall effectiveness of this treatment strategy.

Для цитирования: He H, Yao K, Nie W P, Wang Z, Liang Q, Shu C, Dardik A. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 2015. DOI: 10.1016/j.ejvs.2015.04.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.