MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12037

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2012

Functional response to cardiac resynchronization therapy is associated with improved clinical outcome and absence of appropriate shocks.

Van Boven Nick, Bogaard Kjell, Ruiter Jaap, Kimman Geert, Theuns Dominic, Kardys Isabella, Umans Victor

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

We evaluated clinical outcome and incidence of (in)appropriate shocks in consecutive chronic heart failure (CHF) patients treated with CRT with a defibrillator (CRT-D) according to functional response status. Furthermore, we investigated which factors predict such functional response.

METHODS AND

RESULTS

In a large teaching hospital, 179 consecutive CHF patients received CRT-D in 2005-2010. Patients were considered functional responders if left ventricular ejection fraction (LVEF) increased to ≥ 35% postimplantation. Analysis was performed on 142 patients, who had CRT-D as primary prevention, complete data and a baseline LVEF <35%. Endpoints consisted of all-cause mortality, heart failure (HF) hospitalizations, appropriate shocks and inappropriate shocks. Median follow-up was 3.0 years (interquartile range [IQR] 1.6-4.4) and median baseline LVEF was 20% (IQR 18-25%). The functional response-group consisted of 42 patients. In this group no patients died, none were hospitalized for HF, none received appropriate shocks and 3 patients (7.1%) received ≥ 1 inappropriate shocks. In comparison, the functional nonresponse group consisted of 100 patients, of whom 22 (22%) died (P = 0.003), 17 (17%) were hospitalized for HF (P = 0.007), 17 (17%) had ≥ 1 appropriate shocks (P = 0.003) and 8 (8.1%) received ≥ 1 inappropriate shocks (P = 0.78). Multivariable analysis showed that left bundle branch block (LBBB), QRS duration ≥ 150 milliseconds and no need for diuretics at baseline are independent predictors of functional response.

CONCLUSION

Functional responders to CRT have a good prognosis and rarely need ICD therapy. LBBB, QRS duration ≥ 150 milliseconds and lack of chronic diuretic use predict functional response.

Для цитирования: Van Boven Nick, Bogaard Kjell, Ruiter Jaap, Kimman Geert, Theuns Dominic, Kardys Isabella, Umans Victor. Functional response to cardiac resynchronization therapy is associated with improved clinical outcome and absence of appropriate shocks.. Journal of cardiovascular electrophysiology. 2012. DOI: 10.1111/jce.12037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.