Benefits of endocardial and multisite pacing are dependent on the type of left ventricular electric activation pattern and presence of ischemic heart disease: insights from electroanatomic mapping.
Аннотация
BACKGROUND
There is considerable heterogeneity in the myocardial substrate of patients undergoing cardiac resynchronization therapy (CRT), in particular in the etiology of heart failure and in the location of conduction block within the heart. This may account for variability in response to CRT. New approaches, including endocardial and multisite left ventricular (LV) stimulation, may improve CRT response. We sought to evaluate these approaches using noncontact mapping to understand the underlying mechanisms.
METHODS AND
RESULTS
Ten patients (8 men and 2 women; mean [SD] age 63 [12] years; LV ejection fraction 246%; QRS duration 161 [24] ms) fulfilling conventional CRT criteria underwent an electrophysiological study, with assessment of acute hemodynamic response to conventional CRT as well as LV endocardial and multisite pacing. LV activation pattern was assessed using noncontact mapping. LV endocardial pacing gave a superior acute hemodynamic response compared with conventional CRT (26% versus 37% increase in LV dP/dt(max), respectively; P<0.0005). There was a trend toward further incremental benefit from multisite LV stimulation, although this did not reach statistical significance (P=0.08). The majority (71%) of patients with nonischemic heart failure etiology or functional block responded to conventional CRT, whereas those with myocardial scar or absence of functional block often required endocardial or multisite pacing to achieve CRT response.
CONCLUSIONS
Endocardial or multisite pacing may be required in certain subsets of patients undergoing CRT. Patients with ischemic cardiomyopathy and those with narrower QRS, in particular, may stand to benefit.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.