Stress cardiovascular MR in routine clinical practice: referral patterns, accuracy, tolerance, safety and incidental findings.

Khoo J P, Grundy B J, Steadman C D, Sonnex E P, Coulden R A, McCann G P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The use of stress cardiovascular MR (CMR) to evaluate myocardial ischaemia has increased significantly over recent years. We aimed to assess the indications, incidental findings, tolerance, safety and accuracy of stress CMR in routine clinical practice.

METHODS

We retrospectively examined all stress CMR studies performed at our tertiary referral centre over a 20-month period. Patients were scanned at 1.5 T, using a standardised protocol with routine imaging for late gadolinium enhancement. Angiograms of patients were assessed by an interventional cardiologist blinded to the CMR data.

RESULTS

654 patients were scanned (mean age 65±29 years; 63 inpatients; 9.6%). 14% of patients had incidental extracardiac findings, the commonest being liver or renal cysts (6%) and pulmonary nodules (4%). 639 patients (97.7%) received intravenous adenosine, 10 received intravenous dobutamine and 5 patients had both. Of the 15 patients who received dobutamine, 12 had no side-effects/complications, 2 experienced nausea and 1 chest tightness. Of the 644 patients who received adenosine, 43% experienced minor symptoms, 1% had transient heart block and 0.2% had severe bronchospasm requiring termination of infusion. There were no cases of hospitalisation or myocardial infarction. 241 patients also had coronary angiography. For detecting at least moderate stenosis of ≥50%, sensitivity was 86%, specificity 98% and accuracy 89%. For detecting severe stenoses of ≥70%, sensitivity was 91%, specificity 86% and overall accuracy 90%. These results compare very favourably with previous smaller research studies and meta-analyses.

CONCLUSION

We conclude that stress CMR, with adenosine as the main stress agent, is well tolerated, safe and accurate in routine clinical practice.

Для цитирования: Khoo J P, Grundy B J, Steadman C D, Sonnex E P, Coulden R A, McCann G P. Stress cardiovascular MR in routine clinical practice: referral patterns, accuracy, tolerance, safety and incidental findings.. The British journal of radiology. 2012. DOI: 10.1259/bjr/14829242.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.