MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mrgentox.2019.03.009

Медицинская библиотека · Mutation research. Genetic toxicology and environmental mutagenesis · 2019

Alkaline comet assay results on fresh and one-year frozen whole blood in small volume without cryo-protection in a group of people with different health status.

Milić Mirta, Ožvald Ivan, Vinković Vrček Ivana, Vučić Lovrenčić Marijana, Oreščanin Višnja, Bonassi Stefano, Del Castillo Emilio Rojas

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Using alkaline comet assay, DNA damage tail length (TL) and tail intensity (TI) parameters were compared between fresh whole blood and 1-year frozen small volume whole blood in EDTA at -80 °C without cryo-preservation. The studied group consisted of 25 volunteers with different health conditions who served as their own controls for frozen blood results. Without the purification step after thawing, the results and the usefulness of this protocol for future/retrospective (including re-analysations of putative outliers) studies were analysed. Medical surveillance and blood sampling were done at Merkur University Hospital Zagreb. No significant differences between fresh and frozen blood samples in terms of the mean TL values (mean ± SD: 29.03 ± 12.26 vs. 25.36 ± 6.97, respectively) and the mean TI values (9.19 ± 10.37 vs. 10.17 ± 8.55, respectively), and highly damaged cell percentage were determined among 25 volunteers. Median TI frozen samples values of entire group were within the allowed 10-11% (8.24). At the individual levels, no correlation between fresh and frozen whole blood samples was observed in 11 volunteers who suffered from diabetes mellitus type 2. Strong correlation between fresh/frozen samples was seen for TL (r = 0.64, p < 0.015) and TI (r = 0.71, p < 0.005) in nondiabetic subgroup. Overall, the results demonstrated the usefulness of the 1-year frozen blood without induction of heavily damaged DNA. Due to the different DNA damage behaviour connected with different health conditions, future studies should involve more volunteers, oxidative DNA damage comet assay measurements, the inclusion of a washing step after thawing and inclusion of disease/antioxidant biomarkers.

Для цитирования: Milić Mirta, Ožvald Ivan, Vinković Vrček Ivana, Vučić Lovrenčić Marijana, Oreščanin Višnja, Bonassi Stefano, Del Castillo Emilio Rojas. Alkaline comet assay results on fresh and one-year frozen whole blood in small volume without cryo-protection in a group of people with different health status.. Mutation research. Genetic toxicology and environmental mutagenesis. 2019. DOI: 10.1016/j.mrgentox.2019.03.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.