MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ajts.ajts_92_18

Медицинская библиотека · Asian journal of transfusion science · 2019

High thermal amplitude auto-anti-"N" complicating pretransfusion compatibility tests on a patient with malaria and bladder cancer.

Joshi Sanmukh R, Sheladiya Ankita, Agrawal Vijaykumar N

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Antigen "N" is a high-frequency antigen of the MNS blood groups and carried on glycophorin B that is resistant to enzymatic cleavage by trypsin, and provides differential diagnosis of its antibody specificity to N being present of glycophorin A. Naturally occurring IgM antibodies to N are known to be clinically insignificant, as against the IgG counterpart with clinical relevance.

AIM: Auto-anti-"N" association with the bladder cancer was explored for its clinical significance as well as its interference in grouping anomaly.

MATERIALS AND

METHODS

A warm environment was created while blood sampling for the laboratory work up as the patient had a high-titer auto-cold agglutinin causing spontaneous hemagglutination. The antibody was tested by standard serological methods with the red cell, antisera, and enzymes prepared in house or obtained commercially.

RESULTS

The case was admitted to hospital with high fever and hematuria; he was diagnosed with malaria and bladder cancer. He required transfusions in the face of severe anemia. His blood sample posed problems in compatibility tests due to autoantibody present. Serological workup revealed its specificity as anti-"N."

CONCLUSION

Auto-anti-"N" as a cause of severe anemia could not be attributed to, for concurrent malarial infection. However, its presence may have some association with the underlying malignant condition.

Для цитирования: Joshi Sanmukh R, Sheladiya Ankita, Agrawal Vijaykumar N. High thermal amplitude auto-anti-"N" complicating pretransfusion compatibility tests on a patient with malaria and bladder cancer.. Asian journal of transfusion science. 2019. DOI: 10.4103/ajts.ajts_92_18.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.