Okumura Masanori, Ozaki Yukio, Ishii Junichi, Kan Shino, Naruse Hiroyuki, Matsui Shigeru, Ishikawa Makoto, Hattori Kousuke, Gochi Tomoko, Nakano Tadashi, Yamada Akira, Kato Shigeru, Motoyama Sadako, Sarai Masayoshi, Takagi Yasushi, Ismail Tevfik F, Nomura Masanori, Hishida Hitoshi
Аннотация
BACKGROUND: Restenosis still occurs, even with the sirolimus-eluting stent (SES), and the precise mechanisms and the impact of stent fracture on restensosis have not yet been elucidated.
METHODS AND RESULTS: Intravascular ultrasound (IVUS)-guided SES implantation was performed in 184 lesions in 151 patients with stable and unstable angina. Serial (pre-, post- and follow-up) quantitative coronary angiography analysis was obtained in 169 lesions in 138 patients (angiographic follow-up rate: 91%) and 12-month clinical follow-up was done in all patients. Restenosis occurred in 13 (7.7%) of 169 lesions. Stent fracture occurred in 4 (2.4%) of 169 lesions at follow-up. Of the 13 restenotic lesions, 8 had intimal hyperplasia, 4 had stent fracture, and 1 had late stent thrombosis at 7 months. Although multivariate logistic regression analysis revealed that minimal lumen area (min-LA) post (p=0.027), total stent length (p=0.003) and diabetes (p=0.032) were significant independent predictors of restenosis, univariate analysis showed that stent fracture was more common in the restenosis than in the non-restenosis groups (p=0.001).
CONCLUSIONS: Although min-LA post by IVUS, total stent length by QCA and diabetes are independent predictors for angiographic restenosis, stent fracture occurred in 4 lesions (2.4%) and all of them resulted in restenosis (31% of the restenosis). The impact of stent fracture and its potential role in the development of restenosis deserves further study.
METHODS AND RESULTS: Intravascular ultrasound (IVUS)-guided SES implantation was performed in 184 lesions in 151 patients with stable and unstable angina. Serial (pre-, post- and follow-up) quantitative coronary angiography analysis was obtained in 169 lesions in 138 patients (angiographic follow-up rate: 91%) and 12-month clinical follow-up was done in all patients. Restenosis occurred in 13 (7.7%) of 169 lesions. Stent fracture occurred in 4 (2.4%) of 169 lesions at follow-up. Of the 13 restenotic lesions, 8 had intimal hyperplasia, 4 had stent fracture, and 1 had late stent thrombosis at 7 months. Although multivariate logistic regression analysis revealed that minimal lumen area (min-LA) post (p=0.027), total stent length (p=0.003) and diabetes (p=0.032) were significant independent predictors of restenosis, univariate analysis showed that stent fracture was more common in the restenosis than in the non-restenosis groups (p=0.001).
CONCLUSIONS: Although min-LA post by IVUS, total stent length by QCA and diabetes are independent predictors for angiographic restenosis, stent fracture occurred in 4 lesions (2.4%) and all of them resulted in restenosis (31% of the restenosis). The impact of stent fracture and its potential role in the development of restenosis deserves further study.
Предметные рубрики MeSH
AgedCardiovascular Surgical ProceduresCoronary AngiographyCoronary RestenosisCoronary ThrombosisCoronary VesselsDrug-Eluting StentsEquipment FailureFemaleFollow-Up StudiesHumansHyperplasiaJapanMaleMiddle AgedMultivariate AnalysisProspective StudiesTreatment OutcomeTunica IntimaUltrasonography, Interventional